IDD1 |
Normal mode supply current |
All device functions enabled
All pins unloaded
SDA and SCL high |
|
40 |
48 |
µA |
IDD2 |
Standby mode 1 supply current |
V3P3 and overcurrent monitor enabled
All pins unloaded
All other device functions disabled
SDA and SCL high |
|
14 |
17 |
µA |
IDD3 |
Standby mode 2 supply current |
V3P3 enabled
All pins unloaded
All device functions disabled
SDA and SCL high |
|
12 |
14 |
V |
IDD4 |
Sleep mode supply current |
V3P3 disabled
All pins unloaded
All device functions disabled
SDA and SCL low |
|
1 |
1.5 |
µA |
IVCn |
Input current for selected cell |
All cell voltages equal
Cell balancing disabled
Open cell detection disabled
during cell voltage monitoring |
n = 6 |
|
2.4 |
2.7 |
µA |
n = 1 – 5 |
|
|
< 0.5 |
n = 1 – 5 at 25°C |
|
|
< 0.3 |
∆IVCn |
Cell to cell input current difference |
All cell voltages equal
Cell balancing disabled
Open cell detection disabled |
|
|
< 0.2 |
µA |