SLUSFG2C September 2024 – June 2025 TPS6286A06 , TPS6286A08 , TPS6286A10 , TPS6286B08 , TPS6286B10
PRODUCTION DATA
When the junction temperature exceeds TJSD, the device goes into thermal shutdown, stops switching, and activates the output voltage discharge. When the device temperature falls below the threshold by the hysteresis, the device returns to normal operation automatically with an internal soft start-up. During thermal shutdown, the internal register values are kept.
For TPS6286Bxx, when the junction temperature goes up to TJW, the device gives a pre-warning indicator in the STATUS register. The device keeps running.