SLUSFQ1D December 2024 – November 2026 BQ41Z90
PRODUCTION DATA
A battery fuel gauge circuit board is a challenging environment due to the fundamental incompatibility of high-current traces and ultra-low current semiconductor devices. The best way to protect against unwanted trace-to-trace coupling is with a component placement, such as that shown in Figure 8-2, where the high-current section is on the opposite side of the board from the electronic devices. Clearly this is not possible in many situations due to mechanical constraints. Still, every attempt must be made to route high-current traces away from signal traces, which enter the BQ41Z90 directly. IC references and registers can be disturbed and in rare cases damaged due to magnetic and capacitive coupling from the high-current path. Note that during surge current and ESD events, the high-current traces appear inductive and can couple unwanted noise into sensitive nodes of the gas gauge electronics, as illustrated in Figure 8-3.
Figure 8-2 Separating High- and Low-Current Sections Provides an Advantage in Noise
Immunity
Figure 8-3 Avoid
Close Spacing Between High-Current and Low-Level Signal LinesKelvin voltage sensing is extremely important to accurately measure current and top and bottom cell voltages. Place all filter components as close as possible to the device. Route the traces from the sense resistor in parallel to the filter circuit. Adding a ground plane around the filter network can add additional noise immunity. Figure 8-4 and Figure 8-5 demonstrates correct kelvin current sensing.
Figure 8-4 Sensing
Resistor PCB Layout
Figure 8-5 Sense
Resistor, Ground Shield, and Filter Circuit LayoutSome suggestions to improve the system level resiliency to ESD have been tested and improved the performance significantly: