The BQ41Z90 device supports a random connection sequence of cells to the
device during pack manufacturing.
The
cells
can
be connected to the BQ41Z90
in any order although
Texas Instruments
recommends
to connect VSS and VC0 first. For example, cell-10 in a 16-cell stack
can
be first connected at the input terminals leading to pins VC10 and VC9, then cell-4
can
next be connected at the input terminals leading to pins VC4 and VC3, and so on.
The negative
terminal of cell-1
is
not
required
to connect
first
to
VC0. As another example, consider a cell stack that is already assembled and cells
already interconnected to each other, then the stack is connected to the PCB through
a connector, which is plugged or soldered to the PCB. In this case, the sequence
order in which the connections are made to the PCB can be random in time
and
do not need to be controlled in a certain sequence.
There are, however, some restrictions
to how the cells are connected during manufacturing:
- To avoid misunderstanding,
note that the cells in a stack cannot be randomly connected to
any VC pin on the device, such as the lowest cell
(cell-1) connected to VC15, while the top cell (cell-16) is connected to
VC4, and so on.
Cells
in the stack
must
be connected in ascending pin order, with the lowest cell
(cell-1) connected between VC1 and VC0, the next higher voltage cell
(cell-2) connected between VC2 and VC1, and so on.
- The random cell connection
support is possible due to high voltage tolerance on pins
VC1
to VC16.
Note: VC0 has a lower voltage
tolerance. This is because VC0
must
be connected through the series-cell input resistor to the VSS pin on
the PCB, before any cells are attached to the PCB. Thus, the VC0 pin
voltage is expected to remain close to the VSS pin voltage during cell
attach. If VC0 is not connected through the series resistor to VSS on
the PCB, then cells cannot be connected in random
sequence.
- Each of the
VC1
to VC16 pins includes a diode between the pin and the
adjacent lower cell input pin (that is, between VC16 and VC15, between VC9
and VC8, and so on), which is reverse biased in normal operation. This means
an upper cell input pin
must
not be driven to a low voltage while a lower cell input pin is driven to a
higher voltage, since this
forward
biases
these diodes. During cell attach, the cell input terminals
must
generally be floating before being
connected to the appropriate cell.
The
transient current
is
expected
to
flow briefly when each cell is attached, but the cell
voltages
quickly stabilize to a state without DC current flowing through the diodes.
However, if a large capacitance is included between a cell input pin and
another terminal (such as VSS or another cell input pin), the transient
current
can
become excessive and lead to device heating. Therefore,
Texas
Instruments
recommends
to limit capacitances applied at each cell input pin to the values
recommended in the specifications.
Note: After the
cells are first connected, the
device
requires either a charger attachment or activation of the WAKE pin to
make sure that the device enters normal operating mode. If there is
firmware running then the device can enter SHUTDOWN during the cell
connection phase. The WAKE pin can be used to power up
the device only after the device power supply is
stabilized
to pull up the pin.
See Power Supply Control for further details on the device powering up.