SHUTDOWN mode is an ultra-low power mode where the device is completely powered down except for support circuits enabling the device to be able to exit SHUTDOWN. The primary exit circuit is a small voltage detection circuit that uses the internal RPACK_PD and the external RPACK to detect the VSTARTUP threshold at the PACK pin. RPACK_PD is automatically enabled upon entry to SHUTDOWN but can also be enabled and disabled under FW control.
The device can be configured to enter SHUTDOWN mode automatically based on the top of stack voltage or the minimum cell voltage. If the top-of-stack voltage falls below a programmed stack voltage threshold, or if the minimum cell voltage falls below a programmed cell voltage threshold, the SHUTDOWN mode sequence is automatically initiated. The shutdown based on cell voltage does not apply to cell input pins being used to measure interconnect.
While the BQ41Z90 device is in NORMAL mode or SLEEP mode, the device can also be configured to enter SHUTDOWN mode if the internal temperature measurement exceeds a programmed temperature threshold for a programmed delay if this functionality is enabled through configuration.
See Power Supply Control for more details on powering up from SHUTDOWN mode.