SLUU406A February 2010 – January 2022 CSD16322Q5 , CSD16410Q5A , TPS40303 , TPS40304 , TPS40305
| Test Point | Label | Use | Section |
|---|---|---|---|
| TP1 | VIN | Measurement test point for input voltage | Section 4.3.1 |
| TP2 | GND | Ground test point for input voltage | Section 4.3.1 |
| TP3 | VOUT | Measurement test point for output voltage | Section 4.3.1 |
| TP4 | GND | Ground test point for output voltage | Section 4.3.2 |
| TP5 | CHB | Measurement test point for channel B of loop response | Section 4.3.3 |
| TP6 | SGND | Ground test point for channel B of loop response | Section 4.3.3 |
| TP7 | CHA | Measurement test point for channel A of loop response | Section 4.3.3 |
| TP8 | SGND | Ground test point for channel A of loop response | Section 4.3.3 |
| TP9 | SGND | Ground test point for error amplifier measurements | Section 4.3.4 |
| TP10 | COMP | Measurement test point for error amplifier output voltage | Section 4.3.4 |
| TP11 | FB | Measurement test point for error amplifier input voltage | Section 4.3.4 |
| TP12 | HDRV | Measurement test point for high-side gate driver voltage | Section 4.3.5 |
| TP13 | LDRV | Measurement test point for low-side gate driver voltage | Section 4.3.5 |
| TP14 | PGND | Ground test point for switch node and gate drive voltages | Section 4.3.5 |
| TP15 | SW | Measurement test point for switch node voltage | Section 4.3.5 |
| TP16 | PGOOD | Measurement test point for power good | Section 4.3.6 |
| TP17 | EN/SS | Measurement test point for enable/soft start | Section 4.3.7 |
| TP18 | SGND | Ground test point for power good and enable/soft start | Section 4.3.6 and Section 4.3.7 |