SLVK199 August   2025 TPS7H3024-SP

 

  1.   1
  2.   TPS7H3024-SP Single-Event Effects (SEE)
  3.   Trademarks
  4. Introduction
  5. Single-Event Effects (SEE)
  6. Device and Test Board Information
  7. Irradiation Facility and Setup
  8. LETEFF and Range Calculation
  9. Test Setup and Procedures
  10. Destructive Single-Event Effects (DSEE)
    1. 7.1 Single-Event Latch-Up (SEL) Results
    2. 7.2 Single-Event Burnout (SEB) and Single-Event Gate Rupture (SEGR) Results
  11. Single-Event Transients (SET)
  12. Event Rate Calculations
  13. 10Summary
  14.   A References

Device and Test Board Information

The TPS7H3024-SP is packaged in a 22-pin CFP-HFT ceramic package as shown in Figure 3-1. The TPS7H3024EVM-CVAL was used to evaluate the performance and characteristics of the TPS7H3024-SP under heavy ion radiation. The TPS7H3024EVM-CVAL is shown in Figure 3-2. The configuration used during the heavy-ions test campaign in provided in Figure 3-3.

 Photograph of Delidded TPS7H3024-SP [Left] and Pinout Diagram [Right]Figure 3-1 Photograph of Delidded TPS7H3024-SP [Left] and Pinout Diagram [Right]
Note: The package was delidded to reveal the die face for all heavy-ion testing.
 TPS7H3024EVM-CVAL Top ViewFigure 3-2 TPS7H3024EVM-CVAL Top View
 TPS7H3024EVM-CVAL Schematic for SEE TestingFigure 3-3 TPS7H3024EVM-CVAL Schematic for SEE Testing