SLVK305 October 2026 LMX2624-SP
For Vcc = 3.3V (Nominal) 1 unit was characterized from 83MeV down to 2.76MeV. 20Ne was used to obtain LETEFF of 2.76MeV×cm2/mg.40Ar was used to obtain LETEFF of 7.5 MeV×cm2/mg. 59Co was used to obtain LETEFF of 16MeV×cm2/mg. 84Kr was used to obtain LETEFF of 27MeV×cm2/mg. 109Ag was used to obtain LETEFF of 45MeV×cm2/mg. 129Xe was used to obtain LETEFF of 56MeV×cm2/mg. 169Tm was used to obtain LETEFF of 70MeV×cm2/mg. 197Au was used to obtain LETEFF of 83MeV×cm2/mg. In this device configuration, the output frequency for RFOUT_AP = 191.4MHz and RFOUT_BP = 12.25GHz. Due to RFOUT_BP's high frequency, only RFOUT_AP is characterized below. The Tektronix MSO68B oscilloscope was used to monitor RFOUT_AP and RFOUT_BP signals of the LMX2624-SP with the respective signal triggering off a 1% window. A trigger of 5.2ns was used for RFOUT_AP outputs in this section. Due to oscilloscope bandwitdth, only RFOUT_AP will be characterized in this section. Table 7-10 summarizes the events seen in this mode on RFOUT_AP Output.
| Run Number on Beam | Ion | Angle | Eff LET | Fluence | Flux | Run | RF Output | Trigger Type | Trigger Details (+/-) | Events |
|---|---|---|---|---|---|---|---|---|---|---|
| 11 | Au | 0 | 83 | 5.05E+06 | 4.95E+04 | 1 | RFOUT_AP | Pulse Width | 1% | 172 |
| 12 | Au | 0 | 83 | 5.00E+06 | 4.72E+04 | 2 | RFOUT_AP | Pulse Width | 1% | 209 |
| 43 | Tm | 0 | 70 | 5.05E+06 | 4.90E+04 | 1 | RFOUT_AP | Pulse Width | 1% | 140 |
| 44 | Tm | 0 | 70 | 5.04E+06 | 5.40E+04 | 2 | RFOUT_AP | Pulse Width | 1% | 112 |
| 63 | Xe | 0 | 56 | 3.09E+06 | 4.83E+04 | 1 | RFOUT_AP | Pulse Width | 1% | 94 |
| 64 | Xe | 0 | 56 | 2.97E+06 | 4.80E+04 | 2 | RFOUT_AP | Pulse Width | 1% | 105 |
| 79 | Ag | 0 | 45 | 3.55E+06 | 5.16E+04 | 1 | RFOUT_AP | Pulse Width | 1% | 85 |
| 80 | Ag | 0 | 45 | 3.44E+06 | 5.22E+04 | 2 | RFOUT_AP | Pulse Width | 1% | 88 |
| 93 | Kr | 0 | 27 | 5.00E+06 | 5.35E+04 | 1 | RFOUT_AP | Pulse Width | 1% | 50 |
| 94 | Kr | 0 | 27 | 5.00E+06 | 5.45E+04 | 2 | RFOUT_AP | Pulse Width | 1% | 73 |
| 109 | Co | 0 | 16 | 5.00E+06 | 5.79E+04 | 1 | RFOUT_AP | Pulse Width | 1% | 26 |
| 123 | Ar | 0 | 7.5 | 5.04E+06 | 5.46E+04 | 1 | RFOUT_AP | Pulse Width | 1% | 1 |
| 9 | Ne | 0 | 2.76 | 5.00E+06 | 5.06E+04 | 1 | RFOUT_AP | Pulse Width | 1% | 0 |
A Weibull fit using these events and fluences fromTable 7-10 can be viewed below.
Figure 7-5 Weibull Fit for LMX2624-SP
Device Configuration 3 - RFOUT_AP Output| Parameters | Values |
|---|---|
| Cross Section (cm2) | 3.79 × 10-5 |
| Onset (MeV×cm2/mg) | 2.80 |
| W (MeV×cm2/mg) | 30.00 |
| S | 2.50 |