Over operating junction temperature range (unless otherwise noted)
|
MIN |
NOM |
MAX |
UNIT |
| VIN |
Input voltage range |
2.25 |
|
5.5 |
V |
| VOUT |
Output voltage range |
0.5 |
|
4.5 |
V |
| CIN |
Effective input capacitance (1) |
3 |
|
|
µF |
| COUT |
Effective output capacitance (1) |
12 |
|
200 |
µF |
| IOUT |
Output current range; TPSM828301 |
|
|
1 |
A |
| IOUT |
Output current range; TPSM828302 |
|
|
2 |
A |
| IOUT |
Output current range; TPSM828303 (2) |
|
|
3 |
A |
| IPG |
Power-good input current capability |
|
|
1 |
mA |
| TJ |
Operating junction temperature(2) |
–40 |
|
125 |
°C |
(1) The values given for all the capacitors in the table are effective capacitance, which includes the DC bias effect. Due to the DC bias effect of ceramic capacitors, the effective capacitance is lower than the nominal value when a voltage is applied. Please check the manufacturer´s DC bias curves for the effective capacitance vs DC voltage applied.
(2) In applications where high power dissipation and high ambient temperatures are present, the maximum output current must be derated