10 Revision History
Changes from Revision C (August 2025) to Revision D (July 2026)
- Added SFT_SEL pulldown connection in simplified schematicGo
- Added information regarding leaving the SFT_SEL floating Go
- Added "Input supply hotplug slew rate" specification in the Absolute Maximum Ratings tableGo
- Added "dVin/dt" specification in the Recommended Operating Conditions tableGo
- Changed RSFT_SEL values in the "SHORT-CIRCUIT PROTECTION" section in the Electrical Characteristics tableGo
- Changed "Scalable fast trip Current (inrush)" from "2" to "2xIstart-up peak" in the Electrical Characteristics tableGo
- Removed the maximum limit for "Quick Output Discharge pull-down current" in the Electrical Characteristics tableGo
- Added y-axis title IDS(A) in Allowed Operating Area (AOA)
in startup plotGo
- Changed RSFT_SEL values in Device Functional Modes table Based on Resistor on
SFT_SEL PinGo
- Added note to Stacking Multiple eFuses for Unlimited ScalabilityGo
- Changed RSFT_SEL values in Device Functional Modes table Based on Resistor on
SFT_SEL PinGo
- Updated SFT_SEL connection in Single Device, Standalone Operation Go
- Updated SFT_SEL connection in Device connected in Parallel for High Current
CapabilityGo
- Updated SFT_SEL connection in 54V, 4.3kW Power Path Protection
CircuitGo
- Updated Power Supply RecommendationsGo
- Updated section title from
Transient Protection to Transient Protection and
Other Design ConsiderationsGo
- Updated SFT_SEL connection in Circuit Implementation with Optional Protection
ComponentsGo
Changes from Revision B (May 2025) to Revision C (August 2025)
- Changed RITMR min from 7Ω to 5Ω in the Electrical Characteristics
SectionGo
- Changed ITIMER max ratio from 0.78 to 0.97 in the Electrical Characteristics sectionGo
- Changed GIMON(ACS) min from 18.02µA/A to 17.24µA/A in the Electrical Characteristics SectionGo
- Changed GIMON(ACS) max from 18.71µA/A to 19.84µA/A in the Electrical Characteristics SectionGo
- Updated RON(GHI) typ value from 3.6mΩ to 3.8mΩ in the Electrical Characteristics SectionGo
- Changed Test condition from VDS > VDSCOMP to IOUT↓ to VDS > VDSCOMP to SWEN↓ for TFFT Test in Timing Requirements Section Go
- Changed typ of QOD enable time from 6ms to 16µs in Timing Characteristics Section Go
- Changed typ data of Cdvdt = 68nF to Cdvdt = openGo
- Fixed the Startup AOA graph by removing the DC labelGo