SLVSII7 December 2025 TPSM8D7420 , TPSM8D7620
PRODUCTION DATA
There are two options for compensating the control loop when designing with TPSM8D7x20. External compensation on the COMP pin provides the most configurability, however there are also two internal compensation options to save board space and reduce BOM count. Internal compensation 1 is a higher gain setting and is targeted for better transient performance. Internal compensation 2 has a lower gain setting and is targeted for minimal output capacitance while maintaining stability.
The compensation components RCOMP and CCOMP that form the Type-II compensator can be calculated by analysis of the voltage loop gain and simplified into equations below. The three equations below assume base units for all variables in the equation.
| Device | Rf |
|---|---|
| TPSM8D7620 | 0.1095 |
| TPSM8D7420 | 0.1405 |
Where
When internal compensation is selected, RCOMP is internally set so the RCOMP equation can be resolved to calculate COUT based on desired crossover frequency.
| MSEL COMPx SETTING | TYPICAL GM (μS) | RCOMP(MΩ) | CCOMP(pF) |
|---|---|---|---|
| External | 1000 | External | External |
| Internal 1 | 12 | 1.4 | 20 |
| Internal 2 | 12 | 0.4 | 20 |