SLVSII7 December   2025 TPSM8D7420 , TPSM8D7620

PRODUCTION DATA  

  1.   1
  2. 1 Features
  3. 2 Applications
  4. 3 Description
  5. 4 Device Comparison Table
  6. 5 Pin Configuration and Functions
  7. 6 Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Electrical Characteristics
    6. 6.6 Typical Characteristics
  8. 7 Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1  Input Voltage Range (VIN)
      2. 7.3.2  Bias Supply Regulator (VCC)
      3. 7.3.3  Device Configuration Pin (MSEL)
      4. 7.3.4  Multiphase Output Configuration
      5. 7.3.5  Enable and Adjustable UVLO
      6. 7.3.6  Adjustable Switching Frequency
      7. 7.3.7  Device Synchronization (SYNC)
        1. 7.3.7.1 Clock Locking
      8. 7.3.8  Adjustable Output Voltage (FB)
      9. 7.3.9  Control Loop Compensation (COMP)
      10. 7.3.10 Slope Compensation
      11. 7.3.11 Power-Good Output Voltage Monitoring
      12. 7.3.12 Output Discharge
      13. 7.3.13 Soft-Start (SS)
      14. 7.3.14 Overcurrent Protection (OCP)
      15. 7.3.15 Temperature Output
      16. 7.3.16 Thermal Shutdown
    4. 7.4 Device Functional Modes
      1. 7.4.1 Shutdown Mode
      2. 7.4.2 Standby Mode
      3. 7.4.3 Active Mode
        1. 7.4.3.1 Peak Current Mode Operation
        2. 7.4.3.2 Diode Emulation
        3. 7.4.3.3 FPWM Mode Operation
        4. 7.4.3.4 Minimum On-time (High Input Voltage) Operation
        5. 7.4.3.5 Dropout
        6. 7.4.3.6 Recovery from Dropout
  9. 8 Applications and Implementation
    1. 8.1 Application Information
    2. 8.2 Typical Applications
      1. 8.2.1 Design Requirements
      2. 8.2.2 Detailed Design Procedure
        1. 8.2.2.1 Custom Design With WEBENCH® Tools
        2. 8.2.2.2 Choosing the Switching Frequency
        3. 8.2.2.3 Setting the Output Voltage
        4. 8.2.2.4 Integrated Inductor Considerations
        5. 8.2.2.5 Input Capacitor Selection
        6. 8.2.2.6 VCC and BOOT Capacitors
        7. 8.2.2.7 Output Capacitor Selection
        8. 8.2.2.8 Compensation Selection
      3. 8.2.3 Application Curves
    3. 8.3 2-PH Application
      1. 8.3.1 Design Requirements
      2. 8.3.2 Detailed Design Procedure
      3. 8.3.3 Application Curves 2-PH
    4. 8.4 Power Supply Recommendations
    5. 8.5 Layout
      1. 8.5.1 Layout Guidelines
        1. 8.5.1.1 Thermal Design and Layout
      2. 8.5.2 Layout Example
  10. 9 Device and Documentation Support
    1. 9.1 Device Support
      1. 9.1.1 Third-Party Products Disclaimer
      2. 9.1.2 Development Support
        1. 9.1.2.1 Custom Design With WEBENCH® Tools
    2. 9.2 Documentation Support
      1. 9.2.1 Related Documentation
    3. 9.3 Receiving Notification of Documentation Updates
    4. 9.4 Support Resources
    5. 9.5 Trademarks
    6. 9.6 Electrostatic Discharge Caution
    7. 9.7 Glossary
  11. 10Revision History
  12. 11Mechanical, Packaging, and Orderable Information

Compensation Selection

There are two options for compensating the control loop when designing with TPSM8D7x20. External compensation on the COMP pin provides the most configurability, however there are also two internal compensation options to save board space and reduce BOM count. Internal compensation 1 is a higher gain setting and is targeted for better transient performance. Internal compensation 2 has a lower gain setting and is targeted for minimal output capacitance while maintaining stability.

The compensation components RCOMP and CCOMP that form the Type-II compensator can be calculated by analysis of the voltage loop gain and simplified into equations below. The three equations below assume base units for all variables in the equation.

Equation 15. FM=1Ts×Ma+VIN2-VOUTL
Equation 16. RCOMP=RfN×2×π×fcoRFB_BRFB_B+RFB_T×GMMAX×VIN×FML×IOUTVOUT+C×VIN×FM
Equation 17. CCOMP=tan⁡65°+tan-1⁡fcoIOUT2×π×VOUT×C×1+VOUT×C×Fm×VINIOUT×L2×π×RCOMP×fco
Table 8-4 Control Loop Variables
Device Rf
TPSM8D7620 0.1095
TPSM8D7420 0.1405

Where

  • fco is the desired crossover frequency which is recommended to be kept less than 100kHz.
  • Ma is the slope compensation ramp defined in Section 7.3.10
  • Rf is the current sense to COMP voltage scaling factor
  • N is the number of phases in parallel

When internal compensation is selected, RCOMP is internally set so the RCOMP equation can be resolved to calculate COUT based on desired crossover frequency.

Table 8-5 Internal and External Compensation Parameters
MSEL COMPx SETTING TYPICAL GM (μS) RCOMP(MΩ) CCOMP(pF)
External 1000 External External
Internal 1 12 1.4 20
Internal 2 12 0.4 20