SLVSJY3A August   2026  – October 2026 BQ25350

PRODUCTION DATA  

  1.   1
  2. 1 Features
  3. 2 Applications
  4. 3 Description
  5. 4 Pin Configuration and Functions
  6. 5 Specifications
    1. 5.1 Absolute Maximum Ratings
    2. 5.2 ESD Ratings
    3. 5.3 Recommended Operating Conditions
    4. 5.4 Thermal Information
    5. 5.5 Electrical Characteristics
    6. 5.6 Timing Requirements
    7. 5.7 Typical Characteristics
  7. 6 Detailed Description
    1. 6.1 Overview
    2. 6.2 Functional Block Diagram
    3. 6.3 Feature Description
      1. 6.3.1 Power-On-Reset (POR)
      2. 6.3.2 Device Power Up from Battery
      3. 6.3.3 Device Power Up from Input Source
        1. 6.3.3.1 Input Voltage Limit Threshold Setting (VINDPM Threshold)
        2. 6.3.3.2 Converter Power-Up
        3. 6.3.3.3 Maximum Power Point Tracking for Small PV Panel
        4. 6.3.3.4 Switching Frequency and Dithering Feature
      4. 6.3.4 Power Path Management
        1. 6.3.4.1 Narrow VDC Architecture
        2. 6.3.4.2 Dynamic Power Management
        3. 6.3.4.3 High Impedance (HIZ) Mode
      5. 6.3.5 Battery Charging Management
        1. 6.3.5.1 Autonomous Charging Cycle
        2. 6.3.5.2 Battery Charging Profile
        3. 6.3.5.3 Charging Termination
        4. 6.3.5.4 BATFET Partition
        5. 6.3.5.5 IR Compensation
        6. 6.3.5.6 Thermistor Qualification
          1. 6.3.5.6.1 Temperature Profile in Charge Mode
          2. 6.3.5.6.2 JEITA Charge Rate Scaling
        7. 6.3.5.7 Charging Safety Timers
      6. 6.3.6 Interrupt to Host (INT)
      7. 6.3.7 BATFET Control
        1. 6.3.7.1 Shutdown Mode
        2. 6.3.7.2 System Power Reset
        3. 6.3.7.3 Standby Mode
      8. 6.3.8 Protections
        1. 6.3.8.1 Voltage and Current Monitoring in Battery Only and HIZ Modes
          1. 6.3.8.1.1 Battery Overcurrent Protection
          2. 6.3.8.1.2 Battery Undervoltage Lockout
        2. 6.3.8.2 Voltage and Current Monitoring in Forward Mode
          1. 6.3.8.2.1 Input Overvoltage
          2. 6.3.8.2.2 System Overvoltage Protection (SYSOVP)
          3. 6.3.8.2.3 Forward Converter Cycle-by-Cycle Current Limit
          4. 6.3.8.2.4 System Short
          5. 6.3.8.2.5 Battery Overvoltage Protection (BATOVP)
        3. 6.3.8.3 Thermal Regulation and Thermal Shutdown
          1. 6.3.8.3.1 Thermal Protection in Battery-only Mode
          2. 6.3.8.3.2 Thermal Protection in Forward Mode
    4. 6.4 Device Functional Modes
      1. 6.4.1 Host Mode and Default Mode
      2. 6.4.2 Register Bit Reset
    5. 6.5 Programming
      1. 6.5.1 Serial Interface
        1. 6.5.1.1 Data Validity
        2. 6.5.1.2 START and STOP Conditions
        3. 6.5.1.3 Byte Format
        4. 6.5.1.4 Acknowledge (ACK) and Not Acknowledge (NACK)
        5. 6.5.1.5 Target Address and Data Direction Bit
        6. 6.5.1.6 Single Write and Read
        7. 6.5.1.7 Multi-Write and Multi-Read
      2. 6.5.2 Register Maps
        1. 6.5.2.1 BQ25350 Registers
  8. 7 Application and Implementation
    1. 7.1 Application Information
    2. 7.2 Typical Application
      1. 7.2.1 Design Requirements
      2. 7.2.2 Application Curves
    3. 7.3 Power Supply Recommendations
    4. 7.4 Layout
      1. 7.4.1 Layout Guidelines
      2. 7.4.2 Layout Example
  9. 8 Device and Documentation Support
    1. 8.1 Receiving Notification of Documentation Updates
    2. 8.2 Support Resources
    3. 8.3 Trademarks
    4. 8.4 Electrostatic Discharge Caution
    5. 8.5 Glossary
  10. 9 Revision History
  11. 10Mechanical, Packaging, and Orderable Information
    1.     PACKAGE OPTION ADDENDUM
    2. 10.1 Tape and Reel Information
    3. 10.2 Mechanical Data

Interrupt to Host (INT)

In many applications, the host does not continually poll the charger status registers. Instead, the INT pin may be used to notify the host of a status change with a 256-μs INT pulse. Upon receiving the interrupt pulse, the host may read the flag registers (Charger_Flag_X and FAULT_Flag_X) to determine the event that caused the interrupt, and for each flagged event, read the corresponding status registers (Charger_Status_X and FAULT_Status_X) to determine the current state. Once set to 1, the flag bits remain latched until they are read by the host, which clears them. The status bits, however, are updated whenever there is a change to status and always represent the current state of the system.

The INT events can be masked off to prevent INT pulses from being sent out when they occur, with the exception of the initial power-up interrupt. Interrupt events are masked by setting their mask bit in registers (Charger_Mask_X and FAULT_Mask_X.) Events always cause the corresponding flag bit to be set to 1, regardless of whether or not the interrupt pulse has been masked.