SLVSKG8A April 2026 – June 2026 BQ25853-Q1
PRODUCTION DATA
The device indicates charging state on the open drain STAT pin. The STAT pin can drive an LED. The STAT pin function can be disabled via the DIS_STAT_PIN bit. When disabled, the STAT pin can be controlled to independently pull LOW using the FORCE_STAT_ON bit. The STAT pin is not affected by the Reverse mode and remains OFF during this mode.
| CHARGING STATE | STAT INDICATOR |
|---|---|
| Output powered (CC or CV modes) | LOW |
| HIZ mode, /CE pin high or EN_CE = 0 | HIGH |
| Input removed or Reverse mode active | HIGH |
| Fault condition which disables switching | Blinking at 1Hz |