SLVSLR7 May 2026 DRV8762-Q1
PRODUCTION DATA
The device integrates a current source and a switch between VDRAIN and SHx device pins and between SHx device pin and the device ground for each channel. The switches can be individually enabled and disabled via SPI register bits OSD_Hx and OSD_Lx. If OSD_Hx is 1b, the source current IPHD_SRC of SHx pin is enabled. If OSD_Lx is 1b, the sink current IPHD_SNK of SHx pin is enabled. When any of OSD_Hx and OSD_Lx register bits are set to 1, the VDS overcurrent detection flags, VDS_Hx and VDS_Lx, change from the fault detection flag to the status flag of VDS comparators. The combination of the integrated current sources and VDS status flags can be used for the phase diagnostics such as an open fault detection of motor load, without activating external MOSFETs.
| Fault condition | OSD_HB | OSD_LB | VDS_HB | VDS_LB | VDS_HA | VDS_LA |
|---|---|---|---|---|---|---|
| No Fault | 1 | 0 | 0 | 1 | 0 | 1 |
| 0 | 1 | 1 | 0 | 1 | 0 | |
| Short to GND | 1 | 0 | 1 | 0 | 1 | 0 |
| 0 | 1 | 1 | 0 | 1 | 0 | |
| Short to VBAT | 1 | 0 | 0 | 1 | 0 | 1 |
| 0 | 1 | 0 | 1 | 0 | 1 | |
| Open Load | 1 | 0 | 0 | 1 | Anything other than VDS_xB response | |
| 0 | 1 | 1 | 0 | |||