SLVUDF6 September   2025

 

  1.   1
  2.   Description
  3.   Get Started
  4.   Features
  5.   Applications
  6.   6
  7. 1Evaluation Module Overview
    1. 1.1 Introduction
    2. 1.2 Kit Contents
    3. 1.3 System Description
      1. 1.3.1 Key System Specifications
      2. 1.3.2 End Equipment
      3. 1.3.3 Electricity Meter
    4. 1.4 Device Information
  8. 2Hardware
    1. 2.1 System Overview
      1. 2.1.1 Block Diagram
      2. 2.1.2 Design Considerations
        1. 2.1.2.1 Voltage Measurement - Analog Front End
        2. 2.1.2.2 Current Measurement - Analog Front End
        3. 2.1.2.3 Input Voltage
  9. 3Software
    1. 3.1 Metrology Overview
      1. 3.1.1 Metrology Formulas
      2. 3.1.2 UART for PC GUI Communication
      3. 3.1.3 Direct Memory Access (DMA)
      4. 3.1.4 ADC Setup
      5. 3.1.5 Foreground Process
      6. 3.1.6 Background Process
      7. 3.1.7 Software Function per_sample_dsp ()
      8. 3.1.8 Frequency Measurement and Cycle Tracking
      9. 3.1.9 LED Pulse Generation
  10. 4Implementation Results
    1. 4.1 Evaluation Procedure
      1. 4.1.1 Equipment Setup
      2. 4.1.2 Test Procedure
        1. 4.1.2.1 Working with the Metrology GUI
        2. 4.1.2.2 Calibration
          1. 4.1.2.2.1 Voltage and Current Offset Calibration
          2. 4.1.2.2.2 Voltage and Current Gain Calibration
          3. 4.1.2.2.3 Active Power Gain Calibration
          4. 4.1.2.2.4 Offset Calibration
          5. 4.1.2.2.5 Phase Calibration
    2. 4.2 Performance Data and Results
      1. 4.2.1 Electricity Meter Metrology Accuracy Results
  11. 5Hardware Design Files
    1. 5.1 Schematics
    2. 5.2 PCB Layouts
    3. 5.3 Bill of Materials (BOM)
  12. 6Additional Information
    1. 6.1 Trademarks
  13. 7Compliance Information
    1. 7.1 Compliance and Certifications
  14. 8Related Documentation

Key System Specifications

FEATURESDESCRIPTION
Number of phases1 phase (current measured through a SHUNT), single voltage through a resistor divider
Accuracy class< 0.5%
Dynamic range50mA to 15A
Current SensorSHUNT
Tested current range50mA to 15A
Tested voltage range100V to 240V
AMC130M02 CLKIN frequency8.192MHz
Oversampling ratio (OSR)1024
Digital filter output sample rate4000 samples per second (default) (adjustable per register setting)
Phase compensation implementationSoftware
Selected central processing unit (CPU) clock frequency79.87MHz
System nominal frequency50Hz or 60Hz
Measured parameters
  • Active, reactive, apparent power and energy
  • Root mean square (RMS) current and voltage
  • Power factor
  • Line frequency
Update rate for measured parametersApproximately equal to 1 second
Communication optionsPC graphical user interface (GUI) with a universal asynchronous receiver-transmitter (UART)
Utilized light emitting diodes (LED)2 LEDs: Active energy and reactive energy
Board power supply3.3V to 16V