Keep the setup as similar to step 1-6 in Section 2.2.1.
Go to GUI Charger Settings page, select Li-ion in Choose the Battery type bar, set Battery CV as 4.20V and set Charger, SOH on the top bar as Enable Charger.
Verify if the battery simulator is charged by approximately 50mA
Close the power supply output. Verify if the battery simulator stops charging and starts outputting current when Vout drops below 6.2V . The Vout voltage need to be held at approximately 6.2V when Vout drops below 6.2V if the device is working normally.