SLVUE37 October   2026

 

  1.   1
  2.   Description
  3.   Get Started
  4.   Features
  5.   Applications
  6.   6
  7. 1Evaluation Module Overview
    1. 1.1 Introduction
    2. 1.2 Kit Contents
    3. 1.3 System Description
      1. 1.3.1 Key System Specifications
      2. 1.3.2 End Equipment
      3. 1.3.3 Electricity Meter
      4. 1.3.4 Power Quality Meter, Power Quality Analyzer
    4. 1.4 Device Information
  8. 2Hardware
    1. 2.1 System Overview
      1. 2.1.1 Block Diagram
      2. 2.1.2 Design Considerations
        1. 2.1.2.1 Voltage Measurement - Analog Front End
        2. 2.1.2.2 Current Measurement - Analog Front End
        3. 2.1.2.3 Input Voltage
        4. 2.1.2.4 XDS110 Emulator
        5. 2.1.2.5 Magnetic Tamper Detection With TMAG5273 Linear 3D Hall-Effect Sensor (Not Populated on EVM)
  9. 3Software
    1. 3.1 Metrology Overview
      1. 3.1.1 Metrology Formulas
      2. 3.1.2 UART for PC GUI Communication
      3. 3.1.3 Direct Memory Access (DMA)
      4. 3.1.4 ADC Setup
      5. 3.1.5 Foreground Process
      6. 3.1.6 Background Process
      7. 3.1.7 Software Function per_sample_dsp ()
      8. 3.1.8 Frequency Measurement and Cycle Tracking
      9. 3.1.9 LED Pulse Generation
  10. 4Implementation Results
    1. 4.1 Evaluation Procedure
      1. 4.1.1 Equipment Setup
        1. 4.1.1.1 Jumper Settings for LED and UART
        2. 4.1.1.2 Power Supply Options and Jumper Settings
      2. 4.1.2 Test Procedure
        1. 4.1.2.1 Working With the Metrology GUI
        2. 4.1.2.2 Calibration
          1. 4.1.2.2.1 Voltage and Current Offset Calibration
          2. 4.1.2.2.2 Voltage and Current Gain Calibration
          3. 4.1.2.2.3 Active Power Gain Calibration
          4. 4.1.2.2.4 Offset Calibration
          5. 4.1.2.2.5 Phase Calibration
    2. 4.2 Performance Data and Results
      1. 4.2.1 Electricity Meter Metrology Accuracy Results
      2. 4.2.2 Radiated Emissions Performance
        1. 4.2.2.1 EMI Mitigation Recommendations
  11. 5Hardware Design Files
    1. 5.1 Schematics
    2. 5.2 PCB Layouts
    3. 5.3 Bill of Materials (BOM)
  12. 6Additional Information
    1. 6.1 Trademarks
  13. 7Tools and Software
  14. 8Related Documentation

Current Measurement - Analog Front End

Figure 2-3 shows that the analog front end for current inputs is different from the analog front end for the voltage inputs.

This design has a 300µΩ shunt populated on the board for each phase and neutral. If desired the shunt can be replaced with another by desoldering the populated shunt and connecting the positive and negative leads from the new SHUNT sensor to the solder points.

AMC-ADC-3PH-EVM Analog Front End for Current InputFigure 2-3 Analog Front End for Current Input

The analog front end for current consists of footprints for electromagnetic interference filter beads (R74, R76, and R104), and an RC low-pass filter (R75, R77, C59, C60, and C61) that functions as an anti-aliasing filter.

Equation 2 shows how to calculate the range of differential voltages fed to the current ADC channel for a given maximum current.

Equation 2. VADCSwing,Current,Shunt= ± 2 Rshunt IRMS,max

Using the populated SHUNT value of 300μΩ, the input signal to the current ADC has a voltage swing of ±42.43mV when the maximum current rating of the meter, for example 100A, is applied. This relatively low voltage, when using GAIN = 16 is well within the required Full Scale Range of ±75mV, see the Full-Scale Range table in the AMC131M03 3-Channel, 64-kSPS, Simultaneous-Sampling, 24-Bit, Reinforced Isolated Delta-Sigma ADC With Integrated DC/DC Converter datasheet.

Table 2-1 Full-Scale Range
GAIN SETTINGFSR
1±1.2V
2±600mV
4±300mV
8±150mV
16±75mV
32±37.5mV
64±18.75mV
128±9.375mV