This procedure must be used to put the
device in SYNC mode.
- Use the flowchart to determine the SYNC category.
- Make determinations for OSCin and using SYNC based on the
category
- If Category 4, SYNC cannot be performed in this
setup.
- If Category 3, verify that the maximum
fOSC frequency for SYNC mode is not violated and
there are hardware accommodations to use the SYNC pin.
- If the channel divide is used, determine the IncludedDivide
value from Table 6-11.
- If not done already, divide the N divider and fractional
values by IncludedDivide (Equation 2) to account for the included channel divide.
- Program the device with the VCO_PHASE_SYNC = 1.
- Apply the SYNC, if required
- If Category 2, a rising edge can be sent to the
SYNC pin and the timing of this is not critical.
- If Category 3, the timing of the SYNC signal with
respect to OSCin clock as shown in Table 6-12 must obey.