For the most reliable programming, TI recommends this procedure:
- Apply power to device.
- Program RESET = 1 to reset registers.
- Program registers as shown in the register map in REVERSE order from
highest to lowest.
- Programming of register R114 is only needed one wants
to change the default states for WD_CNTRL or WD_DLY.
- Programming of registers R113 down to R76 is not
required, but if the registers are programmed, the registers must be
done so as the register map shows.
- Programming of registers R75 down to R0 (with FCAL_EN =
1) is required, unless otherwise specified.
- Make sure R0 with FCAL_EN
= 1 is the last programmed register in this step, otherwise the VCO does
not get calibrated.
- Wait 10ms to verify the internal LDOs have settled down.
- Program register R0 one additional time with FCAL_EN = 1 to verify that the VCO
calibration runs from a stable state.