SNAS818C July 2021 – August 2025 CDCDB800
PRODUCTION DATA
The following section provides the layout guidelines to ensure good thermal performance and power supply connections for the CDCDB800.
In Layout Examples, the CDCDB800 has 85Ωdifferential output impedance LP-HCSL format drivers as per register default settings. All transmission lines connected to CKx pins should be 85Ωdifferential impedance, 42.5Ω single-ended impedance to avoid reflections and increased radiated emissions. If 100Ωoutput impedance is enabled, the transmission lines connected to CKx pins should be 100-Ω differential impedance, 50Ωsingle-ended impedance. Take care to eliminate or reduce stubs on the transmission lines.