Multiple reflow cycles can degrade sensor performance. Ideally, restrict the sensor to a single reflow cycle. A second reflow is possible only if the sensing polymer remains clean and undamaged, no-clean paste is used, and peak temperature is under 260°C.
Hand or hot-air Rework is generally not recommended; if necessary, limit the exposure of the device to direct heat, and avoid contaminating fluxes. If any rework is performed, verify sensor accuracy under controlled humidity conditions after rework.