SNVSCP5C April   2025  – August 2026 TPS7H3024-SP , TPS7H3034-SP , TPS7H3124-SP , TPS7H3134-SP

PRODUCTION DATA  

  1.   1
  2. 1 Features
  3. 2 Applications
  4. 3 Description
  5. 4 Device Comparison Table
  6. 5 Pin Configuration and Functions
  7. 6 Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Electrical Characteristics
    6. 6.6 Timing Requirements
    7. 6.7 Quality Conformance Inspection
    8. 6.8 Typical Characteristics
  8. 7 Parameter Measurement Information
  9. 8 Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1 Input Voltage (IN), VLDO, and REFCAP
        1. 8.3.1.1 Undervoltage Lockout (VPOR_IN < VIN < UVLO)
        2. 8.3.1.2 Power-On Reset (VIN < VPOR_IN)
      2. 8.3.2 SR_UVLO
      3. 8.3.3 SENSEx Inputs
        1. 8.3.3.1 VTH_SENSEX and VOUTx_RISE
        2. 8.3.3.2 IHYS_SENSEx and VOUTx_FALL
        3. 8.3.3.3 Input to Output Time Diagrams
        4. 8.3.3.4 Top and Bottom Resistive Divider Design Equations
      4. 8.3.4 MODE
      5. 8.3.5 Output Stages (RESETx, PWRGD, WDO, PULL_UP1, and PULL_UP2)
        1. 8.3.5.1 Push-Pull Outputs
        2. 8.3.5.2 Open-Drain Outputs (TPS7H3124 and TPS7H3134)
      6. 8.3.6 WDI
      7. 8.3.7 User-Programmable TIMERS
        1. 8.3.7.1 DLY_TMR
        2. 8.3.7.2 WD_TMR
    4. 8.4 Device Functional Modes
  10. 9 Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Typical Application
      1. 9.2.1 Window Voltage Monitoring
        1. 9.2.1.1 Design Requirements
        2. 9.2.1.2 Detailed Design Procedure
          1. 9.2.1.2.1 Input Power Supplies and Decoupling Capacitors
          2. 9.2.1.2.2 SR_UVLO Threshold
          3. 9.2.1.2.3 SENSEx Thresholds
        3. 9.2.1.3 Application Curves
      2. 9.2.2 Supervision of Negative Voltage Rails
        1. 9.2.2.1 Negative Voltage Monitoring Example
    3. 9.3 Power Supply Recommendations
    4. 9.4 Layout
      1. 9.4.1 Layout Guidelines
      2. 9.4.2 Layout Example
  11. 10Device and Documentation Support
    1. 10.1 Documentation Support
      1. 10.1.1 Related Documentation
    2. 10.2 Receiving Notification of Documentation Updates
    3. 10.3 Support Resources
    4. 10.4 Trademarks
    5. 10.5 Electrostatic Discharge Caution
    6. 10.6 Glossary
  12. 11Revision History
  13. 12Mechanical, Packaging, and Orderable Information

Negative Voltage Monitoring Example

For the purpose of this discussion the following assumptions are made:

  1. The negative voltage to be monitored (or supervised) is -1.8V at steady-state.
  2. VLDO is used to offset the SENSEx input.
  3. The negative rails needs to be monitored for under voltage (UV).
  4. The rail is considered in regulation when in reach 97% of the final value.
    1. VIN_REGULATION = 97% of -1.8V = -1.746V
  5. The rail is considered not to be on regulation if the voltage is greater than 95% of the final value.
    1. VNOT_IN_REGULATION = 95% of -1.8V = -1.71V

Since the -1.8V needs to be monitored for undervoltage an overvoltage channel is needed. For the TPS7H3x24 with MODE = 0 (logical value) the SENSE2 or SENSE4 can be used for this application. In the case of the TPS7H3x34 with MODE=1 (logical value) any SENSEx channel can be used for this application.

To calculate the top and bottom resistor for the voltage divider we use Equation 35 and Equation 36 as:

Equation 37. RTOPx=-1.71- (-1.746)24 x 10-6= 0.036V24 x 10-6=1,500Ω or 1.5kΩ
Equation 38. RBOTTOMx=1.5kΩ×0.5997-3.29-1.746-0.5997= 1.5kΩ×-2.69-2.345=1720Ω or 1.72kΩ

Using the closest resistor value using 0.1% tolerance resistors the select top and bottom resistors are: 1.5kΩ and 1.75kΩ, respectively. Using the selected resistor we can calculate the expected in regulation and not in regulation voltages. Use Equation 39and Equation 40, to calculate these voltages. The nominal expected in regulation and not in regulation voltages using the selected resistors are: -1.742V and -1.706V, respectively.

Equation 39. VIN_REGULATION= ((1+RTOPxRBOTTOMx)×VTH_SENSEx)-(RTOPxRBOTTOMx×VLDO)-(RTOPx×IHYS_SENSEx)
Equation 40. VNOT_IN_REGULATION= ((1+RTOPxRBOTTOMx)×VTH_SENSEx)-(RTOPxRBOTTOMx×VLDO)