SPRADS4 October   2025 TDA4VM

 

  1.   1
  2.   Abstract
  3.   Trademarks
  4. 1Introduction
  5. 2Instructions
    1. 2.1 Scope
    2. 2.2 HWA Instruction Definition
    3. 2.3 Fault Injection Procedure
      1. 2.3.1 Block Diagram
      2. 2.3.2 Fault Injection: Steps
        1. 2.3.2.1 Underflow Error
        2. 2.3.2.2 Overflow Error
        3. 2.3.2.3 Offset Parity Error
        4. 2.3.2.4 Config Parity Error
          1. 2.3.2.4.1 A FSM Config Parity Error
          2. 2.3.2.4.2 B FSM Config Parity Error
          3. 2.3.2.4.3 C FSM Config Parity Error
          4. 2.3.2.4.4 X FSM Config Parity Error
        5. 2.3.2.5 C READ Error
        6. 2.3.2.6 C Write Error
  6. 3Flow Diagram
    1. 3.1 Code Changes
      1. 3.1.1 Return Hook Definition
      2. 3.1.2 Clear MMA Function
      3. 3.1.3 Sequence Test
  7. 4Summary
  8. 5References

Config Parity Error

An config parity error occurs when a parity mismatch is detected in the HWA_CONFIG register. The procedure on how to inject the HWA_CONFIG parity error are listed in the following steps. All the FSM configurations (A,B,C,X FSM Configurations) are protected by the parity.
  1. The HWAOPEN instruction is used to write HWA_CONFIG and HWA_OFFSET with parity computation enabled and parity checking enabled (PARITYCTRL = NORMAL).
  2. The values in the vector registers are corrupted by software in the specific field to be tested.
  3. The HWAOPEN instruction is again used to write HWA_CONFIG and HWA_OFFSET using the corrupted data from that C7x vector register with the parity computation disabled and parity checking enabled (PARITYCTRL = PNCMCK). In this mode, the originally computed and saved parity value is checked against the parity computed on use in the affected register.
  4. Execute HWAXFER to transfer the content of HWA_CONFIG/HWA_OFFSET and so on to transfer the buffer.
  5. The HWARCV instruction is executed to observe the error