Injecting DC power onto a high-speed
data line introduces risks of signal integrity. The addition of a differential mode
inductor (DMI) network reduces the differential impedance on the line, which leads
to return loss degradation. Imbalances between the two conductors generate
common-mode currents, causing mode conversion and elevated electromagnetic
emissions. Adding series inductance decreases the differential impedance at the
lower frequency end and results in voltage droop performance degradation.
Mitigation Strategies
- Magnetics Selection: Use
specialized high-isolation magnetics designed for a PoDL DMI network. The
differential impedance and coupling factors of a DMI network have a significant
role in PoDL performance.
Increasing the inductor value of a DMI network helps with return loss and
voltage droop. A DMI network typically adds extra differential impedance at
the lower frequency end. Increasing the inductor value shifts the
differential impedance degradation to the lower frequency range and prevents
any effect at the operating frequency range.
A coupling inductor DMI
network selection reduces the mode conversion factor when compared to a two
isolate inductor DMI network. A coupling DMI network filters out any common
mode noise on the line to help with mode conversion. Furthermore, a two
isolated inductor DMI network typically has some tolerance difference
between the two. Having a higher coupling factor further reduces the
differential noise and provides a better mode conversion measurement.
Another advantage of coupling a DMI network also has by adding mutual
factors which increases the differential inductance or impedance on the
line.
However, a higher inductor value typically has lower current support on a
DMI network. If customers want better signal performance with high current
support applications, increasing the size of the DMI network is the tradeoff for
the DMI network:
- Power Loss Optimization:
In the high-voltage system of a radar application, there is always a concern
about the extra power consumption across the CMT network. For example, in the
48V system, there is always an extra power consumption V2/R across
both the PSE and PD board. However, the following PoDL designs in Figure 6-3 and potentially help with this power loss scenario.
Figure 6-3 Figure 6-4 Design 1 and Design 2 of a
PoDL Network to Resolve Power Loss
- Design 1 (left figure):
Moves the common-mode termination before the AC coupling capacitors. This design
eliminates the power loss at the common-mode termination, removing the loss
across that termination entirely.
- Design 2 (right figure):
Connects both wires to the positive power supply and uses the cable shield as
the ground reference. This design also eliminates the power loss across the
common-mode termination and is the approach typically used with shielded
cables.
- PCB layout optimization:
For a rigorous decoupling network optimization and controlled impedance routing,
follow the layout instruction to further improve signal integrity
performance:
- Place the DMI
(differential mode inductor) network with the same layer as the MDI
line.
- Connect vias directly on
the DMI footprint and route the vias with the MDI line on the top
layer.
- Minimize the stubs
between the DMI and MDI lines.
- Prevent the vias from
being too close to the DMI to prevent any impedance drop and mode
conversion.
- Connect the power and
ground polygon pour place in the bottom layer with the DMI network.
- Void under the DMI and
CMC network.
- TI recommends placing a
common mode termination on the bottom layer.
- Keep the MDI lines and
DMI network symmetrical.
- Additional Implementation
Concerns for a PoDL Network:
- Cable Selection:
Cables must be rated for both the differential impedance (100Ω) required
by Ethernet and the current carrying capacity required by the PoDL
load.
- Safety and
Reliability: The implementation must adhere to stringent
automotive safety standards (ISO 26262) to prevent a power fault from
compromising the data integrity of the safety-critical sensing stream.
Implement the use of a PSE source device to stop power transfers when
there is an overcurrent or undercurrent flow, an unexpected
classification, reverse voltage, or current protection.