SWRA689 February 2022 AWR6843 , AWR6843AOP , IWR6843 , IWR6843AOP
Power measurements for the Full Power Down Scheme described in Section 5 are shown below.
| Full Power Scheme Functions | Device Power Consumption (mW) | Power Saved by Function (mW) | Total Power Saved by Scheme (mW) |
|---|---|---|---|
| Startup | 895 | 0 | 0 |
| DSP power down | 738 | 157.2 | 157.2 |
| MSS VCLK 40 | 576 | 162 | 319.2 |
| RF power down | 372.6 | 203.4 | 522.6 |
| APLL and GPADC power down | 217.8 | 154.8 | 677.4 |