TIDUFL1 November   2026 DRV8106-Q1 , DRV81646-Q1 , MSPM0G3519 , TCAN844-Q1 , TPS1200-Q1

 

  1.   1
  2.   Description
  3.   Resources
  4.   Features
  5.   Applications
  6.   6
  7. 1System Description
    1. 1.1 Terminology
    2. 1.2 Key System Specifications
  8. 2System Overview
    1. 2.1 Block Diagram
    2. 2.2 Design Considerations
    3. 2.3 Highlighted Products
      1. 2.3.1 MSPM0G351x-Q1
      2. 2.3.2 TPS65388x-Q1
      3. 2.3.3 TPS1200-Q1
      4. 2.3.4 DRV8106-Q1
      5. 2.3.5 DRV81646-Q1
      6. 2.3.6 DRV81325-Q1
      7. 2.3.7 TCAN844-Q1
      8. 2.3.8 WSS001-Q1
  9. 3System Design Theory
    1. 3.1 Power Tree Design
      1. 3.1.1 Input Power
      2. 3.1.2 Reverse Polarity Protection and Wake-Up
      3. 3.1.3 On-Board Power Rails and PMIC Schematic Design
    2. 3.2 Load Driver Design
      1. 3.2.1 DRV8106-Q1 Design for Pump Motor Drive
      2. 3.2.2 TPS1200-Q1 Design for Load Cut-Off
      3. 3.2.3 DRV81646-Q1 Design for Valve Drive
    3. 3.3 Sensing and Communication Design
    4. 3.4 Processor Schematic Design
    5. 3.5 Diagnostics Design and FuSa Analysis
  10. 4Hardware, Software, Testing Requirements, and Test Results
    1. 4.1 Hardware Requirements
    2. 4.2 Software
    3. 4.3 Test Setup
    4. 4.4 Test Results
      1. 4.4.1 TPS65388x-Q1 Test Results
        1. 4.4.1.1 Power on Sequence of the TPS65388x-Q1
      2. 4.4.2 TPS1200-Q1 Test Results
        1. 4.4.2.1 TPS1200-Q1 Turn-On Characteristics
      3. 4.4.3 Solenoid Valves Test Results
        1. 4.4.3.1 Solenoid Valves Turn-On and Turn-Off Waveforms
      4. 4.4.4 Pump Motor Test Results
        1. 4.4.4.1 Turn ON/OFF Waveforms of the Pump Motor with Discrete Operation Mode
        2. 4.4.4.2 Turn ON/OFF Waveforms of the Pump Motor with Continuous Operation Mode
      5. 4.4.5 WSS001-Q1 Test Results
      6. 4.4.6 Thermal Performance
  11. 5Design and Documentation Support
    1. 5.1 Design Files
      1. 5.1.1 Schematics
      2. 5.1.2 BOM
      3. 5.1.3 PCB Layout Recommendations
        1. 5.1.3.1 Layout Prints
    2. 5.2 Tools and Software
    3. 5.3 Documentation Support
    4. 5.4 Support Resources
    5. 5.5 Trademarks
  12. 6About the Author

Turn ON/OFF Waveforms of the Pump Motor with Continuous Operation Mode

Figure 1-1 shows the waveforms of the pump motor in continuous operating mode at 15Hz. Compared to the discrete mode, the peak transient current is significantly lower because the motor does not have sufficient time to decelerate between cycles; the mechanical momentum maintains a higher base speed.

TIDA-020111 Pump Motor Continuous Operation Mode
          Waveforms (15Hz) Figure 4-10 Pump Motor Continuous Operation Mode Waveforms (15Hz)

Figure 4-11 shows the turn-off transient characteristics of the pump motor. When the PWM signal transitions to low, the HSS of the pump motor is turned off. The motor current is then conducted through the paralleled diode, which clamps the motor voltage to the negative diode's forward voltage VF. Once the motor current decays to zero, the diode ceases conduction, and the motor voltage becomes equal to the generated EMF, which is proportional to the motor's rotational speed.

In this reference design, the turn-on and turn-off driving strength of the DRV8106-Q1 is configured to 62mA through the SPI, as observed in the red waveform.

TIDA-020111 Pump Motor Turn OFF Waveforms Figure 4-11 Pump Motor Turn OFF Waveforms