Applications 1-lead ECG, Optical-HRM Number of input channels 4 Resolution (Bits) 22 Number of LEDs 6 Interface type I2C Operating temperature range (°C) -40 to 85 Rating Catalog
Applications 1-lead ECG, Optical-HRM Number of input channels 4 Resolution (Bits) 22 Number of LEDs 6 Interface type I2C Operating temperature range (°C) -40 to 85 Rating Catalog
DSBGA (YZ) 30 4.8 mm² 2.4 x 2
  • Supports signal acquisition of up to 24 phases
  • Flexible allocation of 6 LED, 4 PD in each PPG phase
  • Synchronized PPG/ECG signal acquisition with each phase configurable as PPG or ECG, and at different data rates
  • Synchronized PPG/ECG supports up to 1 kHz data rate
  • ECG-only mode supports up to 4 kHz data rate
  • PPG signal chain:
    • System SNR up to 108-dB at 16 µA PD current
    • Low current for continuous operation on a wearable device with a typical value: 15 µA for an LED, 20 µA for the receiver
  • PPG Transmitter:
    • Supports common anode LED configuration
    • 8-Bit programmable LED current with range adjustable from 25 mA to 250 mA
    • Mode to fire two LEDs in parallel with independent per-phase current control
    • Programmable LED on-time per-phase
    • Simultaneous support of 6 LEDs for SpO2, HRM, or multi-wavelength HRM
  • PPG Receiver:
    • Supports 4 time-multiplexed photodiode inputs
    • 2 parallel receivers to sample two PD channels simultaneously
    • Individual ambient offset subtraction DAC at each TIA Input with 8-bit per-phase control and range adjustable up to 255-µA
    • Individual LED offset subtraction DAC at each TIA input with 5-bit per-phase control and
      15.5-µA range
    • Close to 100 dB ambient rejection up to 10 Hz
    • Noise filtering with programmable bandwidth
    • Transimpedance Gain: 3.7 kΩ to 1 MΩ
  • ECG Signal Chain
    • 1-lead ECG with RLD output for bias
    • INA gain programmable from 1.6 – 13
    • <1 µVrms input noise (in a 1-150 Hz bandwidth) at 4-kHz sample rate
    • Integrated 450 Hz Low Pass Filter
    • AC, DC lead-off detect with 3.125-100 nA current and programmable interrupt
  • Supports external clock and internal oscillator modes
  • Option to acquire data synchronized with a system master clock
  • Automatic cancellation of DC from ambient, LED
  • FIFO with 128-sample depth
  • I2C interface
  • 2.6-mm × 2.1-mm DSBGA, 0.4-mm pitch
  • Supplies: Rx: 1.7 V-1.9 V (LDO bypass); 1.9 V-3.6 V (LDO enabled), Tx: 3 V-5.5 V, IO: 1.7-3.6 V
  • Supports operation with 2 supplies - 1.8 V, 5 V
  • Supports signal acquisition of up to 24 phases
  • Flexible allocation of 6 LED, 4 PD in each PPG phase
  • Synchronized PPG/ECG signal acquisition with each phase configurable as PPG or ECG, and at different data rates
  • Synchronized PPG/ECG supports up to 1 kHz data rate
  • ECG-only mode supports up to 4 kHz data rate
  • PPG signal chain:
    • System SNR up to 108-dB at 16 µA PD current
    • Low current for continuous operation on a wearable device with a typical value: 15 µA for an LED, 20 µA for the receiver
  • PPG Transmitter:
    • Supports common anode LED configuration
    • 8-Bit programmable LED current with range adjustable from 25 mA to 250 mA
    • Mode to fire two LEDs in parallel with independent per-phase current control
    • Programmable LED on-time per-phase
    • Simultaneous support of 6 LEDs for SpO2, HRM, or multi-wavelength HRM
  • PPG Receiver:
    • Supports 4 time-multiplexed photodiode inputs
    • 2 parallel receivers to sample two PD channels simultaneously
    • Individual ambient offset subtraction DAC at each TIA Input with 8-bit per-phase control and range adjustable up to 255-µA
    • Individual LED offset subtraction DAC at each TIA input with 5-bit per-phase control and
      15.5-µA range
    • Close to 100 dB ambient rejection up to 10 Hz
    • Noise filtering with programmable bandwidth
    • Transimpedance Gain: 3.7 kΩ to 1 MΩ
  • ECG Signal Chain
    • 1-lead ECG with RLD output for bias
    • INA gain programmable from 1.6 – 13
    • <1 µVrms input noise (in a 1-150 Hz bandwidth) at 4-kHz sample rate
    • Integrated 450 Hz Low Pass Filter
    • AC, DC lead-off detect with 3.125-100 nA current and programmable interrupt
  • Supports external clock and internal oscillator modes
  • Option to acquire data synchronized with a system master clock
  • Automatic cancellation of DC from ambient, LED
  • FIFO with 128-sample depth
  • I2C interface
  • 2.6-mm × 2.1-mm DSBGA, 0.4-mm pitch
  • Supplies: Rx: 1.7 V-1.9 V (LDO bypass); 1.9 V-3.6 V (LDO enabled), Tx: 3 V-5.5 V, IO: 1.7-3.6 V
  • Supports operation with 2 supplies - 1.8 V, 5 V

The AFE49I30 is an analog front-end for optical bio-sensing/ PPG and ECG measurement applications. The device supports up to six switching light-emitting diodes (LEDs) and up to four photodiodes. Up to 24 signal phases can be defined and the PPG or ECG signals can be acquired from each phase in a synchronized manner.

The AFE49I30 is an analog front-end for optical bio-sensing/ PPG and ECG measurement applications. The device supports up to six switching light-emitting diodes (LEDs) and up to four photodiodes. Up to 24 signal phases can be defined and the PPG or ECG signals can be acquired from each phase in a synchronized manner.

Descargar Ver vídeo con transcripción Video
Information

Solicitar más información

La hoja de datos completa y otros recursos de diseño están disponibles bajo NDA. Solicitar ahora

Productos similares que pueden interesarle

open-in-new Comparar alternativas
Misma funcionalidad con diferente configuración de pines que el dispositivo comparado
AFE4950 ACTIVO AFE integrado ultrapequeño para la monitorización óptica portátil de la frecuencia cardiaca y SpO2 ECG+PPG AFE with integrated high-pass, low-pass filters optimized for dry electrodes.

Documentación técnica

star =Principal documentación para este producto seleccionada por TI
No se encontraron resultados. Borre su búsqueda y vuelva a intentarlo.
Ver todo 1
Tipo Título Fecha
* Data sheet AFE49I30 Ultra-Small, Integrated AFE With FIFO for Multi-Sensor Wearable, Optical Heart-Rate Monitoring and Bio-sensing datasheet PDF | HTML 13 abr 2020

Diseño y desarrollo

Para conocer los términos adicionales o los recursos necesarios, haga clic en cualquier título de abajo para ver la página de detalles cuando esté disponible.

Placa de evaluación

AFE44S30EVM — AFE integrado AFE4430 para detección biológica óptica portátil con módulo de evaluación FIFO y SPI

The AFE44S30 evaluation module (EVM) is a platform for evaluating the AFE44S30 device, which is an analog front end (AFE) for optical biosensing applications, such as heart-rate monitoring (HRM) and saturation of peripheral capillary oxygen (SpO2). AFE44S30 supports eight switching (...)

Placa de evaluación

AFE49I30EVM — AFE integrado de potencia ultrabaja AFE49I30 para módulo de evaluación de detección biológica óptica

The AFE49I30 evaluation module (EVM) is a platform for expediting and evaluating system development activities related to the AFE49I30 product. AFE49I30 is an analog front end (AFE) for optical biosensing applications, such as heart-rate monitoring (HRM) and saturation of peripheral capillary (...)

Controlador o biblioteca

BSECUR-3P-ALGORITHMS — Algoritmos B SECUR ECG y servicios de diseño de electrodos

HeartKey is a powerful and accurate set of ECG algorithms, ready for integration into the next generation low power low memory consumer / IoT & medical devices such as smartwatches, smart clothing, medical, automotive, smart home devices and hand-held devices. HeartKey is comprised of advanced (...)
Desde: B Secur
Herramienta de simulación

PSPICE-FOR-TI — PSpice® para herramienta de diseño y simulación de TI

PSpice® for TI is a design and simulation environment that helps evaluate functionality of analog circuits. This full-featured, design and simulation suite uses an analog analysis engine from Cadence®. Available at no cost, PSpice for TI includes one of the largest model libraries in the (...)
Paquete Pasadores Descargar
DSBGA (YZ) 30 Ver opciones

Pedidos y calidad

Información incluida:
  • RoHS
  • REACH
  • Marcado del dispositivo
  • Acabado de plomo/material de la bola
  • Clasificación de nivel de sensibilidad a la humedad (MSL) / reflujo máximo
  • Estimaciones de tiempo medio entre fallas (MTBF)/fallas en el tiempo (FIT)
  • Contenido del material
  • Resumen de calificaciones
  • Monitoreo continuo de confiabilidad
Información incluida:
  • Lugar de fabricación
  • Lugar de ensamblaje

Los productos recomendados pueden tener parámetros, módulos de evaluación o diseños de referencia relacionados con este producto de TI.

Soporte y capacitación

Foros de TI E2E™ con asistencia técnica de los ingenieros de TI

El contenido lo proporcionan “tal como está” TI y los colaboradores de la comunidad y no constituye especificaciones de TI. Consulte los términos de uso.

Si tiene preguntas sobre la calidad, el paquete o el pedido de productos de TI, consulte el soporte de TI. ​​​​​​​​​​​​​​

Videos