Device type Receiver Number of input channels 8 Active supply current (typ) (mA) 133 Operating temperature range (°C) 0 to 85 Interface type LVDS Features Analog Front End (AFE) Rating Catalog
Device type Receiver Number of input channels 8 Active supply current (typ) (mA) 133 Operating temperature range (°C) 0 to 85 Interface type LVDS Features Analog Front End (AFE) Rating Catalog
NFBGA (ZCF) 135 135 mm² (9 mm × 15 mm)
  • 8-Channel Complete Analog Front-End
    • LNA, VCAT, PGA, LPF, ADC, and CW Mixer
  • Programmable Gain Low-Noise Amplifier (LNA)
    • 24-, 18-, 12-dB Gain
    • 0.25-, 0.5-, 1-VPP Linear Input Range
    • 0.63-, 0.7-, 0.9-nV/rtHz Input Referred Noise
    • Programmable Active Termination
  • 40-dB Low-Noise Voltage Controlled Attenuator
    (VCAT)
  • 24-/30-dB Programmable Gain Amplifier (PGA)
  • Third-Order Linear Phase Low-Pass Filter (LPF)
    • 10,15, 20, 30 MHz
  • 14-Bit Analog-to-Digital Converter (ADC)
    • 77 dBFS SNR at 65 MSPS
    • LVDS Outputs
  • Noise, Power Optimizations (Without Digital
    Demodulator)
    • 158 mW/CH at 0.75 nV/rtHz, 65 MSPS
    • 101 mW/CH at 1.1 nV/rtHz, 40 MSPS
    • 80 mW/CH at CW Mode
  • Excellent Device-to-Device Gain Matching
    • ±0.5 dB (Typical) and ±1 dB (Maximum)
  • Digital I/Q Demodulator after ADC
    • Wide Range Demodulation Frequency
    • <1 kHz Frequency Resolution
    • Decimation Filter Factor M = 1 to 32
    • 16xM Tap FIR Decimation Filter
    • LVDS Rate Reduction after Demodulation
    • On-Chip RAM With 32 Preset Profiles
  • Low Harmonic Distortion
  • Low-Frequency Sonar Signal Processing
  • Fast and Consistent Overload Recovery
  • Passive Mixer for Continuous Wave Doppler
    (CWD)
    • Low Close-in Phase Noise –156 dBc/Hz at 1
      kHz off 2.5-MHz Carrier
    • Phase Resolution of 1/16λ
    • Support 16×, 8×, 4×, and 1× CW Clocks
    • 12-dB Suppression on Third and Fifth
      Harmonics
    • Flexible Input Clocks
  • Small Package: 15 mm × 9 mm, 135-BGA
  • 8-Channel Complete Analog Front-End
    • LNA, VCAT, PGA, LPF, ADC, and CW Mixer
  • Programmable Gain Low-Noise Amplifier (LNA)
    • 24-, 18-, 12-dB Gain
    • 0.25-, 0.5-, 1-VPP Linear Input Range
    • 0.63-, 0.7-, 0.9-nV/rtHz Input Referred Noise
    • Programmable Active Termination
  • 40-dB Low-Noise Voltage Controlled Attenuator
    (VCAT)
  • 24-/30-dB Programmable Gain Amplifier (PGA)
  • Third-Order Linear Phase Low-Pass Filter (LPF)
    • 10,15, 20, 30 MHz
  • 14-Bit Analog-to-Digital Converter (ADC)
    • 77 dBFS SNR at 65 MSPS
    • LVDS Outputs
  • Noise, Power Optimizations (Without Digital
    Demodulator)
    • 158 mW/CH at 0.75 nV/rtHz, 65 MSPS
    • 101 mW/CH at 1.1 nV/rtHz, 40 MSPS
    • 80 mW/CH at CW Mode
  • Excellent Device-to-Device Gain Matching
    • ±0.5 dB (Typical) and ±1 dB (Maximum)
  • Digital I/Q Demodulator after ADC
    • Wide Range Demodulation Frequency
    • <1 kHz Frequency Resolution
    • Decimation Filter Factor M = 1 to 32
    • 16xM Tap FIR Decimation Filter
    • LVDS Rate Reduction after Demodulation
    • On-Chip RAM With 32 Preset Profiles
  • Low Harmonic Distortion
  • Low-Frequency Sonar Signal Processing
  • Fast and Consistent Overload Recovery
  • Passive Mixer for Continuous Wave Doppler
    (CWD)
    • Low Close-in Phase Noise –156 dBc/Hz at 1
      kHz off 2.5-MHz Carrier
    • Phase Resolution of 1/16λ
    • Support 16×, 8×, 4×, and 1× CW Clocks
    • 12-dB Suppression on Third and Fifth
      Harmonics
    • Flexible Input Clocks
  • Small Package: 15 mm × 9 mm, 135-BGA

The AFE5809 device is a highly-integrated analog front-end (AFE) solution specifically designed for ultrasound systems in which high performance and small size are required. The AFE5809 device integrates a complete time-gain-control (TGC) imaging path and a CWD path. The device also enables users to select one of various power and noise combinations to optimize system performance. Therefore, the AFE5809 device is a suitable ultrasound AFE solution not only for high-end systems, but also for portable ones.

The AFE5809 device contains eight channels of voltage controlled amplifier (VCA), 14, and 12-bit ADC, and CW mixer. The VCA includes LNA, VCAT, PGA, and LPF. The LNA gain is programmable to support 250 mVPP to 1 VPP input signals. Programmable active termination is also supported by the LNA. The ultra-low noise VCAT provides an attenuation control range of 40 dB and improves overall low-gain SNR, which benefits harmonic imaging and near-field imaging. The PGA provides gain options of 24 and 30 dB. Before the ADC, a LPF can be configured as 10, 15, 20, or 30 MHz to support ultrasound applications with different frequencies. In addition, the signal chain of the AFE5809 device can handle signal frequency lower than 100 kHz, which enables the device to be used in both sonar and medical applications. The high-performance 14-bit/65-MSPS ADC in the AFE5809 device achieves 77-dBFS SNR. It ensures excellent SNR at low chain gain. The ADC’s LVDS outputs enable flexible system integration desired for miniaturized systems.

The AFE5809 device integrates a low-power passive mixer and a low-noise summing amplifier to accomplish on-chip CWD beamformer. 16 selectable phase-delays can be applied to each analog input signal. Meanwhile, a unique third- and fifth-order harmonic suppression filter is implemented to enhance CW sensitivity.

The AFE5809 device also includes a digital in-phase and quadrature (I/Q) demodulator and a low-pass decimation filter. The main purpose of the demodulation block is to reduce the LVDS data rate and improve overall system power efficiency. The I/Q demodulator can accept ADC output with up to 65 MSPS sampling rate and 14-bit resolution. For example, after digital demodulation and 4× decimation filtering, the data rate for either in-phase or quadrature output is reduced to 16.25 MSPS and the data resolution is improved to 16 bits, consequently. Hence, the overall LVDS trace reduction can be a factor of 2. This demodulator can be bypassed and powered down completely if it is not needed.

The AFE5809 device is available in a 15-mm × 9-mm, 135-pin BGA package, and it is specified for operation from 0°C to 85°C.

Note: AFE5809 with date code later than 2014, that is date code >41XXXX, has below additional features which can be enabled by Register 61[15,14,13]. Existing analog performance remains the same.

  • 61[13] enables an additional voltage clamp at the V2I input of the PGA. This limits the amount of overload signal the PGA sees.
  • 61[14] enables a first-order 5-MHz LPF filter to suppress signals >5 MHz or high-order harmonics.
  • 61[15] enables a –6-dB PGA clamp setting. The actual PGA output is less than the ADC’s full-scale amplitude, 2 Vpp.

The AFE5809 device is a highly-integrated analog front-end (AFE) solution specifically designed for ultrasound systems in which high performance and small size are required. The AFE5809 device integrates a complete time-gain-control (TGC) imaging path and a CWD path. The device also enables users to select one of various power and noise combinations to optimize system performance. Therefore, the AFE5809 device is a suitable ultrasound AFE solution not only for high-end systems, but also for portable ones.

The AFE5809 device contains eight channels of voltage controlled amplifier (VCA), 14, and 12-bit ADC, and CW mixer. The VCA includes LNA, VCAT, PGA, and LPF. The LNA gain is programmable to support 250 mVPP to 1 VPP input signals. Programmable active termination is also supported by the LNA. The ultra-low noise VCAT provides an attenuation control range of 40 dB and improves overall low-gain SNR, which benefits harmonic imaging and near-field imaging. The PGA provides gain options of 24 and 30 dB. Before the ADC, a LPF can be configured as 10, 15, 20, or 30 MHz to support ultrasound applications with different frequencies. In addition, the signal chain of the AFE5809 device can handle signal frequency lower than 100 kHz, which enables the device to be used in both sonar and medical applications. The high-performance 14-bit/65-MSPS ADC in the AFE5809 device achieves 77-dBFS SNR. It ensures excellent SNR at low chain gain. The ADC’s LVDS outputs enable flexible system integration desired for miniaturized systems.

The AFE5809 device integrates a low-power passive mixer and a low-noise summing amplifier to accomplish on-chip CWD beamformer. 16 selectable phase-delays can be applied to each analog input signal. Meanwhile, a unique third- and fifth-order harmonic suppression filter is implemented to enhance CW sensitivity.

The AFE5809 device also includes a digital in-phase and quadrature (I/Q) demodulator and a low-pass decimation filter. The main purpose of the demodulation block is to reduce the LVDS data rate and improve overall system power efficiency. The I/Q demodulator can accept ADC output with up to 65 MSPS sampling rate and 14-bit resolution. For example, after digital demodulation and 4× decimation filtering, the data rate for either in-phase or quadrature output is reduced to 16.25 MSPS and the data resolution is improved to 16 bits, consequently. Hence, the overall LVDS trace reduction can be a factor of 2. This demodulator can be bypassed and powered down completely if it is not needed.

The AFE5809 device is available in a 15-mm × 9-mm, 135-pin BGA package, and it is specified for operation from 0°C to 85°C.

Note: AFE5809 with date code later than 2014, that is date code >41XXXX, has below additional features which can be enabled by Register 61[15,14,13]. Existing analog performance remains the same.

  • 61[13] enables an additional voltage clamp at the V2I input of the PGA. This limits the amount of overload signal the PGA sees.
  • 61[14] enables a first-order 5-MHz LPF filter to suppress signals >5 MHz or high-order harmonics.
  • 61[15] enables a –6-dB PGA clamp setting. The actual PGA output is less than the ADC’s full-scale amplitude, 2 Vpp.

Descargar Ver vídeo con transcripción Video

Documentación técnica

No se encontraron resultados. Borre su búsqueda y vuelva a intentarlo.
Ver todo 3
Documentación principal Tipo Título Opciones de formato Descargar la versión más reciente en inglés Fecha
* Hoja de datos AFE5809 Fully Integrated, 8-Channel Ultrasound Analog Front End With Passive CW Mixer, and Digital I/Q Demodulator, 0.75 nV/rtHz, 14, 12-Bit, 65 MSPS, 158 mW/CH datasheet (Rev. E) PDF | HTML 25/08/2014
Guía de diseño SONAR Receiver Path Sub-System Using the AFE5809 Design Guide 23/11/2014
Nota sobre la aplicación Understanding Serial LVDS Capture in High-Speed ADCs 10/07/2013

Diseño y desarrollo

Para conocer los términos adicionales o los recursos necesarios, haga clic en cualquier título de abajo para ver la página de detalles cuando esté disponible.

Placa de evaluación

AFE5809EVM — Módulo de evaluación AFE5809

El AFE5809 consiste en una solución de circuito frontal analógico (AFE) altamente integrada que se diseñó en concreto para sistemas de ultrasonido en los que se necesitan alto rendimiento y tamaño reducido. El AFE5809 integra una ruta completa de adquisición de imágenes de control de ganancia (...)

Guía del usuario: PDF
Productos y hardware compatibles
En inventario
Límite:
??asset.out-of-stock-ti_es_MX??
No disponible
GUI para el módulo de evaluación (EVM)

DATACONVERTERPRO-SW — Instalador de interfaz gráfica de usuario (GUI) profesional de convertidor de datos de alta velocidad, v5.31

Esta interfaz gráfica de usuario (GUI) de convertidor de datos de alta velocidad pro es un programa para PC (compatible con Windows® XP/7/10) que está diseñado para ayudar en la evaluación de la mayoría de los convertidores de datos de alta velocidad (convertidor de señal analógica a digital [ADC] (...)

Productos y hardware compatibles
GUI para el módulo de evaluación (EVM)

SLOC276 — AFE5809EVM GUI

Productos y hardware compatibles
Modelo de simulación

AFE5809 PSpice Model

SLOM334.ZIP (74 KB) - Modelo PSpice
Productos y hardware compatibles
Modelo de simulación

AFE5809 PSpice Transient Model

SLOM331.ZIP (46 KB) - Modelo PSpice
Productos y hardware compatibles
Modelo de simulación

AFE5809 TINA-TI Reference Design

SLOM335.TSC (106 KB) - Diseño de referencia TINA-TI
Productos y hardware compatibles
Modelo de simulación

AFE5809 TINA-TI Spice Model

SLOM336.ZIP (63 KB) - Modelo TINA-TI Spice
Productos y hardware compatibles
Modelo de simulación

AFE5809 TINA-TI Transient Reference Design

SLOM333.TSC (63 KB) - Diseño de referencia TINA-TI
Productos y hardware compatibles
Modelo de simulación

AFE5809 TINA-TI Transient Spice Model

SLOM332.ZIP (35 KB) - Modelo TINA-TI Spice
Productos y hardware compatibles
Diseño de referencia

TIDA-00419 — Diseño de referencia del subsistema de ruta del receptor SONAR con un extremo frontal analógico de 8

This reference design is a demonstration of a SONAR receive-path sub-system using the integrated analog front end (AFE) AFE5809. AFE5809 features eight channels of analog signal conditioning  (LNA + VCAT + PGA) and digital processing (ADC + digital demodulator) that brings a high (...)

Productos y hardware compatibles
Encapsulado Pines Símbolos CAD, huellas y modelos 3D
NFBGA (ZCF) 135 Ultra Librarian

Pedidos y calidad

Los productos recomendados pueden tener parámetros, módulos de evaluación o diseños de referencia relacionados con este producto de TI.

Soporte y capacitación

Foros de TI E2E™ con asistencia técnica de los ingenieros de TI

El contenido lo proporcionan “tal como está” TI y los colaboradores de la comunidad y no constituye especificaciones de TI. Consulte los términos de uso.

Si tiene alguna pregunta sobre calidad, encapsulados o pedido de productos de TI, consulte el servicio de asistencia de TI. ​​​​​​​​​​​​​​

Videos