ホーム データ コンバータ 統合型やスペシャル ファンクションの各データ コンバータ 医療用 AFE バイオセンシング AFE

ADS1194

アクティブ

低消費電力、4 チャネル、16 ビット、アナログ フロント エンド、ECG 用

製品詳細

Applications 3-lead ECG, 5-lead ECG, 6-lead ECG, Patient monitoring Number of input channels 4 Resolution (Bits) 16 Interface type SPI Operating temperature range (°C) 0 to 70 Rating Catalog
Applications 3-lead ECG, 5-lead ECG, 6-lead ECG, Patient monitoring Number of input channels 4 Resolution (Bits) 16 Interface type SPI Operating temperature range (°C) 0 to 70 Rating Catalog
TQFP (PAG) 64 144 mm² (12 mm × 12 mm) NFBGA (ZXG) 64 64 mm² (8 mm × 8 mm)
  • Eight Low-Noise PGAs and
    Eight High-Resolution ADCs (ADS1198)
  • Low Power: 0.55mW/channel
  • Input-Referred Noise:
    12µVPP (150Hz BW, G = 6)
  • Input Bias Current: 200pA
  • Data Rate: 125SPS to 8kSPS
  • CMRR: –105dB
  • Programmable Gain: 1, 2, 3, 4, 6, 8, or 12
  • Supports AAMI EC11, EC13, IEC60601-1, IEC60601-2-27, and IEC60601-2-51 Standards
  • Supplies: Unipolar or Bipolar
    • Analog: 2.7V to 5.25V
    • Digital: 1.65V to 3.6V
  • Built-In Right Leg Drive Amplifier, Lead-Off Detection, WCT, Test Signals
  • Pace Detection Channel Select
  • Built-In Oscillator and Reference
  • Flexible Power-Down, Standby Mode
  • SPI™-Compatible Serial Interface
  • Operating Temperature Range:
    0°C to +70°C
  • Eight Low-Noise PGAs and
    Eight High-Resolution ADCs (ADS1198)
  • Low Power: 0.55mW/channel
  • Input-Referred Noise:
    12µVPP (150Hz BW, G = 6)
  • Input Bias Current: 200pA
  • Data Rate: 125SPS to 8kSPS
  • CMRR: –105dB
  • Programmable Gain: 1, 2, 3, 4, 6, 8, or 12
  • Supports AAMI EC11, EC13, IEC60601-1, IEC60601-2-27, and IEC60601-2-51 Standards
  • Supplies: Unipolar or Bipolar
    • Analog: 2.7V to 5.25V
    • Digital: 1.65V to 3.6V
  • Built-In Right Leg Drive Amplifier, Lead-Off Detection, WCT, Test Signals
  • Pace Detection Channel Select
  • Built-In Oscillator and Reference
  • Flexible Power-Down, Standby Mode
  • SPI™-Compatible Serial Interface
  • Operating Temperature Range:
    0°C to +70°C

The ADS1194/6/8 are a family of multichannel, simultaneous sampling, 16-bit, delta-sigma (ΔΣ) analog-to-digital converters (ADCs) with a built-in programmable gain amplifier (PGA), internal reference, and an onboard oscillator.

With its high levels of integration and exceptional performance, the ADS1194/6/8 family enables the creation of scalable medical instrumentation systems at significantly reduced size, power, and overall cost.

The ADS1194/6/8 have a flexible input multiplexer per channel that can be independently connected to the internally-generated signals for test, temperature, and lead-off detection. Additionally, any configuration of input channels can be selected for derivation of the right leg drive (RLD) output signal. The ADS1194/6/8 operate at data rates as high as 8kSPS, thereby allowing the implementation of software pace detection. Lead-off detection can be implemented internal to the device, either with a pull-up/pull-down resistor or an excitation current sink/source. Three integrated amplifiers generate the Wilson Center Terminal (WCT) and the Goldberger terminals (GCT) required for a standard 12-lead medical electrocardiogram (ECG).

Multiple ADS1194/6/8 devices can be cascaded in high channel count systems in a daisy-chain configuration.

Package options include a tiny 8mm × 8mm, 64-ball BGA and a TQFP-64. Both packages are specified over the temperature range of 0°C to +70°C.

The ADS1194/6/8 are a family of multichannel, simultaneous sampling, 16-bit, delta-sigma (ΔΣ) analog-to-digital converters (ADCs) with a built-in programmable gain amplifier (PGA), internal reference, and an onboard oscillator.

With its high levels of integration and exceptional performance, the ADS1194/6/8 family enables the creation of scalable medical instrumentation systems at significantly reduced size, power, and overall cost.

The ADS1194/6/8 have a flexible input multiplexer per channel that can be independently connected to the internally-generated signals for test, temperature, and lead-off detection. Additionally, any configuration of input channels can be selected for derivation of the right leg drive (RLD) output signal. The ADS1194/6/8 operate at data rates as high as 8kSPS, thereby allowing the implementation of software pace detection. Lead-off detection can be implemented internal to the device, either with a pull-up/pull-down resistor or an excitation current sink/source. Three integrated amplifiers generate the Wilson Center Terminal (WCT) and the Goldberger terminals (GCT) required for a standard 12-lead medical electrocardiogram (ECG).

Multiple ADS1194/6/8 devices can be cascaded in high channel count systems in a daisy-chain configuration.

Package options include a tiny 8mm × 8mm, 64-ball BGA and a TQFP-64. Both packages are specified over the temperature range of 0°C to +70°C.

ダウンロード 字幕付きのビデオを表示 ビデオ

技術資料

結果が見つかりませんでした。検索条件をクリアしてから、再度検索を試してください。
11 をすべて表示
上位の文書 タイプ タイトル フォーマットオプション 最新の英語版をダウンロード 日付
* データシート Low-Power, 8-Channel, 16-Bit Analog Front-End for Biopotential Measurements データシート (Rev. C) 2011/11/29
アプリケーション・ノート Digital Filter Types in Delta-Sigma ADCs (Rev. A) PDF | HTML 2023/03/29
e-Book(PDF) Fundamentals of Precision ADC Noise Analysis (Rev. A) 2020/06/19
アナログ デザイン ジャーナル How delta-sigma ADCs work, Part 1 (Rev. A) 2016/09/19
e-Book(PDF) Best of Baker's Best: Precision Data Converters -- Delta-Sigma ADCs 2015/03/19
ユーザー・ガイド TIPD111 Verified Design Reference Guide 2013/06/18
アナログ デザイン ジャーナル How delta-sigma ADCs work, Part 2 2011/11/09
アプリケーション・ノート Improving Common-Mode Rejection Using the Right-Leg Drive Amplifier 2011/07/06
アプリケーション・ノート Thermal Noise Analysis in ECG Applications 2011/05/03
アプリケーション・ノート Respiration Rate Measurement Using Impedance Pneumography 2011/03/01
アプリケーション・ノート Analog Front-End Design for ECG Systems Using Delta-Sigma ADCs (Rev. A) 2010/04/13

設計と開発

その他のアイテムや必要なリソースを参照するには、以下のタイトルをクリックして詳細ページをご覧ください。

評価ボード

ADS1198ECGFE-PDK — ADS1198ECGFE-PDK フロント・エンド、パフォーマンス・デモ・キット

The ADS1198ECG FE is a reference design for the ADS1198, a simultaneous sampling, 16-bit, delta-sigma (ΔΣ) analog-to-digital converter (ADC) with a built-in programmable gain amplifier (PGA), internal reference, and an onboard oscillator. The ADS1198 incorporates all of the features (...)

サポート対象の製品とハードウェア
在庫あり
制限:
??asset.out-of-stock-ti_ja_JP??
入手不可
シミュレーション・モデル

ADS119x IBIS Model (Rev. C)

SBAM080C.ZIP (144 KB) - IBIS モデル
サポート対象の製品とハードウェア
計算ツール

ANALOG-ENGINEER-CALC — PC software analog engineer's calculator

アナログ エンジニア向けカリキュレータは、アナログ回路設計エンジニアが日常的に使用する反復的な計算の多くを迅速化します。この PC ベース ツールはグラフィカル インターフェイスにより、帰還抵抗を使用したオペアンプのゲイン設定から、A/D コンバータ (ADC) のドライブ バッファ回路の安定化に最適な部品の選択に至るまで、一般的に行われている各種計算のリストを表示します。

スタンドアロン ツールとして使用できるほか、『アナログ回路設計式一覧ポケット ガイド』で説明されているコンセプトと組み合わせることもできます。

サポート対象の製品とハードウェア
リファレンス・デザイン

TIDA-00096 — Bluetooth Low Energy を使用したワイヤレス心拍モニタ

Bluetooth Low Energy(BLE)対応のワイヤレス心拍モニタは、顧客がバッテリ動作の 3 チャネル健康管理/フィットネス用心電計(ECG)アプリケーション向けの最終製品を開発するために使用できるリファレンス デザインとして提供されています。  ADS1293 は、3 つの高分解能 ECG チャネルが特長の高集積ローパワー アナログ フロント エンド(AFE)です。  CC2541 システム オン チップ(SoC)によってプラットフォームに BLE ワイヤレス機能が追加され、構成可能な iOS アプリケーションを介して iPhone(R)や (...)

サポート対象の製品とハードウェア
リファレンス・デザイン

TIPD197 — ECG でのソフトウェア ペースメーカー検出のためのリファレンス デザイン

この回路は、ADS129x に内蔵された PACE_OUT バッファから出力される心電図信号を調整およびデジタル化し、人工ペースメーカーのアーティファクトを検出するように設計されています。シグナル コンディショナと高速 SAR(逐次比較型)ADC の入力ドライバとして動作するオペアンプを搭載しています。

サポート対象の製品とハードウェア
パッケージ ピン数 CAD シンボル、フットプリント、および 3D モデル
TQFP (PAG) 64 Ultra Librarian
NFBGA (ZXG) 64 Ultra Librarian

購入と品質

推奨製品には、この TI 製品に関連するパラメータ、評価基板、またはリファレンス デザインが存在する可能性があります。

サポートとトレーニング

TI E2E™ フォーラムでは、TI のエンジニアからの技術サポートを提供

コンテンツは、TI 投稿者やコミュニティ投稿者によって「現状のまま」提供されるもので、TI による仕様の追加を意図するものではありません。使用条件をご確認ください。

TI 製品の品質、パッケージ、ご注文に関するお問い合わせは、TI サポートをご覧ください。​​​​​​​​​​​​​​

ビデオ シリーズ

ビデオをすべて表示

ビデオ