AFE4950
- Supports simultaneous and synchronized acquisition of up to 24 PPG and a single-lead ECG signal.
- Flexible allocation of 8 LED, 4 PD in each phase
- ECG signal chain:
- 1-lead ECG signal acquisition up to 2 kHz
- RLD output to drive a third electrode
- Input noise : 0.7 µV-rms
- Supports up to ±0.65 V differential DC offset and +/-0.55 V common mode range
- Programmable INA gain: 11, 21
- High-pass filter with quick saturation recovery
- Integrated 300 Hz anti-aliasing low pass filter
- AC, DC lead-off detect: 2.9 nA to 92.5 nA
- Low power continuous lead-on detection
- Impedance signal chain
- Continuous low-power monitoring of impedance between 2 electrodes
- 7 MΩ range
- 300 Ω noise on 620 kΩ
- PPG Transmitter:
- 8-Bit Programmable LED Current with range adjustable from 25 mA to 250 mA
- Mode to fire two LEDs in parallel
- Support of 8 LEDs in Common Anode configuration for SpO2, Multi-Wavelength HRM
- PPG Receiver:
- 2 parallel receivers (two sets of TIA/ filter)
- Supports 4 Time-Multiplexed Photodiode Inputs to each Receiver
- 8-bit Ambient Offset subtraction at each TIA input with 256 µA range
- 8-bit LED Offset Subtraction DAC with 64 µA range
- Automatic ambient cancellation and dynamic LED DC cancellation at TIA input
- Ambient rejection close to 100 dB up to 10 Hz
- Noise filtering with programmable bandwidth
- Trans-impedance Gain: 3.7 kΩ to 1 MΩ
- Accurate, Continuous Heart-Rate Monitoring:
- System SNR up to 109-dB at 16 µA PD current
- Low Current for Continuous Operation on a Wearable Device with a Typical Value: 15-µA for an LED, 20-µA for the Receiver
- External clock and internal oscillator modes
- Acquire data synchronized with system master clock
- FIFO with 256-sample Depth
- SPI, I2C interfaces: Selectable by pin
- 2.6-mm × 2.5-mm DSBGA, 0.4-mm Pitch
- Supplies: Rx:1.7-1.9V (LDO Bypass); 1.9-3.6V (LDO Enabled), Tx:3-5.5V, IO:1.7-RX_SUP
The AFE4950 device is an analog front-end (AFE) for synchronized signal acquisition of PPG and ECG signals. The device can also be used for optical bio-sensing applications, such as heart-rate monitoring (HRM) and saturation of peripheral capillary oxygen (SpO2). The ECG signal chain supports 2- and 3-electrode configurations and has an integrated Right leg drive (RLD) buffer. The ECG signal chain can also be used to do a continuous, low-power monitoring of the impedance between pair of electrodes.
추가 정보 요청
전체 데이터시트 및 기타 설계 리소스는 NDA에 따라 제공됩니다. 지금 요청
기술 자료
유형 | 직함 | 날짜 | ||
---|---|---|---|---|
* | Data sheet | AFE4950 Ultra-Small, Integrated AFE for Wearable Optical Heart-Rate Monitoring, SpO2 and Electrical Bio-sensing datasheet (Rev. B) | PDF | HTML | 2021/07/15 |
Product overview | ECG and Cuffless Blood Pressure Monitoring With Integrated AFE | PDF | HTML | 2023/10/30 | |
Product overview | Photoplethysmography (PPG) With Integrated AFE for Optical Biosensing | PDF | HTML | 2023/10/30 | |
Application brief | ECG Signal Acquisition on Wearables | PDF | HTML | 2022/11/15 | |
Application brief | Measuring Oxygen Saturation (SpO2) on Wearables | PDF | HTML | 2022/11/14 | |
Application brief | Optical Heart Rate Monitoring (OHRM) on Wearables | PDF | HTML | 2022/11/14 | |
Application brief | Cuffless Blood Pressure Monitoring on Wearables | PDF | HTML | 2022/11/09 | |
Technical article | Solving 5 challenges of ECG signal acquisition in wearables | PDF | HTML | 2021/07/21 |
설계 및 개발
추가 조건 또는 필수 리소스는 사용 가능한 경우 아래 제목을 클릭하여 세부 정보 페이지를 확인하세요.
AFE4950EVM — AFE4950 웨어러블 광학 심박수 모니터링을 위한 초소형 통합 AFE를 위한 평가 모듈
AFE4950 EVM(평가 모듈)은 AFE4950 제품과 관련된 평가 및 시스템 개발 활동을 신속하게 수행할 수 있도록 설계되었습니다. AFE4950은 PPG 및 ECG 신호의 동기화된 신호 수집을 위한 아날로그 프론트 엔드(AFE)입니다. AFE4950은 HRM(심박수 모니터링) 및 SpO2(주변 모세혈관 산소포화도) 등의 광학 바이오센싱 애플리케이션에도 사용할 수 있습니다.
ECG 신호 체인은 2 및 3 전극 구성을 지원하며, 통합된 RLD(Right-leg Drive) 버퍼를 제공합니다. ECG 신호 체인은 한 쌍의 전극 (...)
BSECUR-3P-ALGORITHMS — B SECUR ECG Algorithms and Electrode Design Services
PSPICE-FOR-TI — TI 설계 및 시뮬레이션 툴용 PSpice®
TI 설계 및 시뮬레이션 환경용 PSpice는 기본 제공 라이브러리를 이용해 복잡한 혼합 신호 설계를 시뮬레이션할 수 있습니다. 레이아웃 및 제작에 (...)
패키지 | 핀 | CAD 기호, 풋프린트 및 3D 모델 |
---|---|---|
DSBGA (YBG) | 36 | Ultra Librarian |
주문 및 품질
- RoHS
- REACH
- 디바이스 마킹
- 납 마감/볼 재질
- MSL 등급/피크 리플로우
- MTBF/FIT 예측
- 물질 성분
- 인증 요약
- 지속적인 신뢰성 모니터링
- 팹 위치
- 조립 위치
권장 제품에는 본 TI 제품과 관련된 매개 변수, 평가 모듈 또는 레퍼런스 디자인이 있을 수 있습니다.