SNAS771C June 2018 – May 2026 LMK05318
PRODUCTION DATA
Refer to the PDF data sheet for device specific package drawings
There are two manual input selection modes that can be set by a register: Manual with Auto-Fallback and Manual with Auto-Holdover. In either manual mode, the input selection can be done through register control (see Table 7-3) or hardware pin control (see Table 7-4).
| DPLL_REF_MAN_REG_SEL (R251[4]) | DPLL_REF_MAN_SEL (R251[5]) | SELECTED INPUT |
|---|---|---|
| 0 | 0 | PRIREF |
| 1 | 0 | SECREF |
| REFSEL (PIN 8) | DPLL_REF_MAN_SEL (R251[5]) | SELECTED INPUT |
|---|---|---|
| 0 | 1 | PRIREF |
| Float (VIM) | 1 | Auto Select |
| 1 | 1 | SECREF |
The reference input selection flowchart is shown in Figure 7-15.
Figure 7-15 Reference Input Selection Flowchart