SLLS007E July   1985  – March 2024 SN75ALS192

PRODUCTION DATA  

  1.   1
  2. Features
  3. Applications
  4. Description
  5. Pin Configuration and Functions
  6. Specifications
    1. 5.1 Absolute Maximum Ratings
    2. 5.2 Dissipation Rating Table
    3. 5.3 Recommended Operating Conditions
    4. 5.4 Thermal Information
    5. 5.5 Electrical Characteristics
    6. 5.6 Switching Characteristics
    7. 5.7 Typical Characteristics Operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied.
  7. Parameter Measurement Information
  8. Device Functional Modes
  9. Device and Documentation Support
    1. 8.1 Receiving Notification of Documentation Updates
    2. 8.2 Support Resources
    3. 8.3 Trademarks
    4. 8.4 Electrostatic Discharge Caution
    5. 8.5 Glossary
  10. Revision History
  11. 10Mechanical, Packaging, and Orderable Information

Package Options

Refer to the PDF data sheet for device specific package drawings

Mechanical Data (Package|Pins)
  • NS|16
  • N|16
  • D|16
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Switching Characteristics

VCC = 5 V, TA = 25°C (see Figure 6-2)
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
tPLH Propagation delay time, low-to-high-level output S1 and S2 open, CL = 30 pF 6 13 ns
tPHL Propagation delay time, high-to-low-level output S1 and S2 open, CL = 30 pF 9 14 ns
Output-to-output skew S1 and S2 open, CL = 30 pF 3 6 ns
tPZH Output enable time to high level S1 open and S2 closed 11 15 ns
tPZL Output enable time to low level S1 closed and S2 open 16 20 ns
tPHZ Output disable time from high level S1 open and S2 closed, CL = 10 pF 8 15 ns
tPLZ Output disable time from low level S1 and S2 closed, CL = 10 pF 18 20 ns