Over operating free-air temperature range, unless
otherwise noted(1)
|
MIN |
MAX |
UNIT |
| VDD(2) |
Supply voltage |
|
18 |
V |
| VID(3) |
Differential input voltage |
|
±VDD |
V |
| VI
(any input) |
Input voltage |
–0.3 |
VDD |
V |
| II |
Input current |
|
±5 |
mA |
| IO |
Output current |
|
±30 |
mA |
|
Duration of short-circuit current at (or less
than) TA = 25°C(4) |
Unlimited |
|
|
Continuous total power dissipation |
See Dissipation Ratings |
|
| TA |
Operating free-air temperature |
C
suffix |
0 |
70 |
°C |
| I
suffix |
–40 |
85 |
| Tstg |
Storage temperature |
–65 |
150 |
°C |
|
Lead temperature 1.6mm (1/16 inch) from case for
10 seconds |
|
260 |
°C |
(1) Stresses beyond those listed under absolute maximum
ratings may cause permanent damage to the device. These are stress
ratings only, and functional operation of the device at these or any other
conditions beyond those indicated under recommended operating conditions
is not implied. Exposure to absolute-maximum-rated conditions for extended
periods may affect device reliability.
(2) All voltage values, except differential voltages, are with
respect to network ground.
(3) Differential voltages are at the IN+ with respect to IN–.
(4) The output is able to be shorted to either supply. Limit
temperature, supply voltages, or both to not exceed the maximum dissipation
ratings (see
Section 7.1.6).