SBAS906 March 2018 TLV320ADC3100
PRODUCTION DATA.
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
ADC interface | ADC interface word length | BCLK | WCLK | Reserved | Tri-State DOUT | ||
R/W-00h | R/W-00h | R/W-0h | R/W-0h | R-0h | R/W-0h |
Bit | Field | Type | Reset | Description |
---|---|---|---|---|
7:6 | ADC interface | R/W | 00h | 00: ADC interface = I2S
01: ADC interface = DSP 10: ADC interface = RJF 11: ADC interface = LJF |
5:4 | ADC interface word length | R/W | 00h | 00: ADC interface word length = 16 bits
01: ADC interface word length = 20 bits 10: ADC interface word length = 24 bits 11: ADC interface word length = 32 bits |
3 | BCLK | R/W | 0h | 0: BCLK is input
1: BCLK is output |
2 | WCLK | R/W | 0h | 0: WCLK is input
1: WCLK is output |
1 | Reserved | R | 0h | Reserved. Do not write any value other than reset value. |
0 | Tri-State DOUT | R/W | 0h | 0: Tri-stating of DOUT: disabled
1: Tri-stating of DOUT: enabled |