When in AUTO_LPM state, the device wakes up and changes the LPM_STATUS bit to 0 when there is a load current increase beyond the IEXIT_LPM_AUTO threshold. The LPM_STATUS_1 bit in the GLOBAL_FAULT_TYPE register is set to 1 when in AUTO_LPM state and is read clear which enables the system to tell if the device had transitioned to the AUTO_LPM state since the GLOBAL_FAULT_TYPE register is last read. An ECU load current demand increase above the IEXIT_LPM_AUTO threshold activates the transition to the ACTIVE state. Note, in this load increase scenario the device does not pull the FLT / WAKE_SIG low.
If there is a larger ECU load current demand increase or output short circuit above the ISCP_LPM_AUTO, the device turns off the internal FET for that channel and retries in tRETRY,INT with IOCP set as the overcurrent protection threshold. In this scenario, the device pulls the FLT / WAKE_SIG pin low when there is a load current increase beyond the ISCP_LPM_AUTO threshold. The device registers a fault as over-current protection fault only if the overcurrent is also confirmed in the ACTIVE state.
Depending on the load step magnitude, the device transitions to the ACTIVE state in different ways. Figure 8-22, Figure 8-23, and Figure 8-24 showcase how the device responds to different load step magnitudes.