JAJSAR0B March 2007 – October 2017 LM95214
PRODUCTION DATA.
The Local Limit register range is 0°C to 127°C. The value programmed in this register is used to determine a local temperature error event.
Register Name | Command Byte
(Hex) |
Read/
Write |
D7 | D6 | D5 | D4 | D3 | D2 | D1 | D0 | POR Default (Hex) |
---|---|---|---|---|---|---|---|---|---|---|---|
Local Tcrit Limit | 0×40 | R/W | 0 | 64 | 32 | 16 | 8 | 4 | 2 | 1 | 0×55 |
Bit(s) | Bit Name | Read/Write | Description |
---|---|---|---|
7 | 0 | R0 | Read only bit will always report 0. |
6 | 64 | R/W | bit weight 64°C |
5 | 32 | R/W | bit weight 32°C |
4 | 16 | R/W | bit weight 16°C |
3 | 8 | R/W | bit weight 8°C |
2 | 4 | R/W | bit weight 4°C |
1 | 2 | R/W | bit weight 2°C |
0 | 1 | R/W | bit weight 1°C |