JAJSAR0B March   2007  – October 2017 LM95214

PRODUCTION DATA.  

  1. 特長
  2. アプリケーション
  3. 概要
    1.     リモート1温度エラー、TA=TD
  4. 改訂履歴
  5. 概要(続き)
  6. Pin Configuration and Functions
    1.     Pin Functions
  7. Specifications
    1. 7.1 Absolute Maximum Ratings
    2. 7.2 ESD Ratings
    3. 7.3 Recommended Operating Conditions
    4. 7.4 Thermal Information
    5. 7.5 Electrical Characteristics: Temperature-to-Digital Converter
    6. 7.6 Logic Electrical Characteristics: Digital DC Characteristics
    7. 7.7 Switching Characteristics: SMBus Digital
    8. 7.8 Typical Characteristics
  8. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1 Conversion Sequence
      2. 8.3.2 Power-On-Default States
      3. 8.3.3 SMBus Interface
      4. 8.3.4 Temperature Conversion Sequence
        1. 8.3.4.1 Digital Filter
      5. 8.3.5 Fault Queue
      6. 8.3.6 Temperature Data Format
      7. 8.3.7 SMBDAT Open-Drain Output
      8. 8.3.8 TCRIT1, TCRIT2, and TCRIT3 Outputs
      9. 8.3.9 TCRIT Limits and TCRIT Outputs
    4. 8.4 Device Functional Modes
      1. 8.4.1 Diode Fault Detection
      2. 8.4.2 Communicating With the LM95214
      3. 8.4.3 Serial Interface Reset
      4. 8.4.4 One-Shot Conversion
    5. 8.5 Register Maps
      1. 8.5.1 LM95214 Registers
        1. 8.5.1.1 Value Registers
          1. 8.5.1.1.1 Local Value Registers
          2. 8.5.1.1.2 Remote Temperature Value Registers With Signed Format
          3. 8.5.1.1.3 Remote Temperature Value Registers With Unsigned Format
        2. 8.5.1.2 Diode Configuration Register
          1. 8.5.1.2.1 Remote 1-4 Offset
        3. 8.5.1.3 Configuration Registers
          1. 8.5.1.3.1 Main Configuration Register
          2. 8.5.1.3.2 Conversion Rate Register
          3. 8.5.1.3.3 Channel Conversion Enable
          4. 8.5.1.3.4 Filter Setting
          5. 8.5.1.3.5 1-Shot
        4. 8.5.1.4 Status Registers
          1. 8.5.1.4.1 Common Status Register
          2. 8.5.1.4.2 Status 1 Register (Diode Fault)
          3. 8.5.1.4.3 Status 2 (TCRIT1)
          4. 8.5.1.4.4 Status 3 (TCRIT2)
          5. 8.5.1.4.5 Status 4 (TCRIT3)
        5. 8.5.1.5 Mask Registers
          1. 8.5.1.5.1 TCRIT1 Mask Register
          2. 8.5.1.5.2 TCRIT2 Mask Registers
          3. 8.5.1.5.3 TCRIT3 Mask Register
        6. 8.5.1.6 Limit Registers
          1. 8.5.1.6.1 Local Limit Register
          2. 8.5.1.6.2 Remote Limit Registers
          3. 8.5.1.6.3 Common Tcrit Hysteresis Register
        7. 8.5.1.7 Identification Registers
  9. Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Typical Application
      1. 9.2.1 Design Requirements
    3. 9.3 Diode Non-Ideality
      1. 9.3.1 Diode Non-Ideality Factor Effect on Accuracy
      2. 9.3.2 Calculating Total System Accuracy
      3. 9.3.3 Compensating for Different Non-Ideality
  10. 10Power Supply Recommendations
  11. 11Layout
    1. 11.1 Layout Guidelines
    2. 11.2 Layout Example
  12. 12デバイスおよびドキュメントのサポート
    1. 12.1 ドキュメントの更新通知を受け取る方法
    2. 12.2 コミュニティ・リソース
    3. 12.3 商標
    4. 12.4 静電気放電に関する注意事項
    5. 12.5 Glossary
  13. 13メカニカル、パッケージ、および注文情報

パッケージ・オプション

メカニカル・データ(パッケージ|ピン)
サーマルパッド・メカニカル・データ
発注情報

コミュニティ・リソース

The following links connect to TI community resources. Linked contents are provided "AS IS" by the respective contributors. They do not constitute TI specifications and do not necessarily reflect TI's views; see TI's Terms of Use.

    TI E2E™オンライン・コミュニティ TIのE2E(Engineer-to-Engineer)コミュニティ。エンジニア間の共同作業を促進するために開設されたものです。e2e.ti.comでは、他のエンジニアに質問し、知識を共有し、アイディアを検討して、問題解決に役立てることができます。
    設計サポート TIの設計サポート 役に立つE2Eフォーラムや、設計サポート・ツールをすばやく見つけることができます。技術サポート用の連絡先情報も参照できます。