There are two levels of thermal protection for the device.
Overtemperature is monitored locally on each regulator.
OT for BUCK1-3: If a thermal monitor on the buck rails reaches a threshold higher than TOTTH, the device enters ERROR mode. Leaving ERROR mode is only possible if the temperature is below TOTTH – TOTHY.
OT for BOOST/LDO: If the temperature monitor of the BOOST or the LDO reaches the TOTTH threshold, the corresponding regulator is switched off.
Overtemperature Shutdown: is monitored on a central die position. In case the TSDTH is reached, the device enters shutdown mode. It leaves shutdown when the TSD sensor is below TSDTH – TSDHY. This event internally generates a POR.