JAJU528B August 2022 – January 2023 OPA388-Q1
Simulate an isolation error condition by connecting the chassis ground line to HV positive. To understand the behavior of error conditions, the measurements were performed at different battery voltages.
Figure 3-28 HV Positive
Error 100 V at No Resistance
Figure 3-29 HV Positive
Error 100 V at 100-kΩ Resistance| HV BATTERY VOLTAGE (SUPPLIED AND MEASURED) |
MEASURED REFERENCE VOLTAGE | PEAK ISO_POS VOLTAGE | PEAK ISO_NEG VOLTAGE |
|---|---|---|---|
| 100 | 2.499 | 2.542 | 2.9683 |
| 200 | 2.499 | 2.542 | 3.3904 |
| 300 | 2.499 | 2.542 | 3.8126 |
| 400 | 2.499 | 2.542 | 4.2352 |
| HV BATTERY VOLTAGE (SUPPLIED AND MEASURED) |
MEASURED REFERENCE VOLTAGE | PEAK ISO_POS VOLTAGE | PEAK ISO_NEG VOLTAGE |
|---|---|---|---|
| 100 | 2.499 | 2.511 | 2.9364 |
| 200 | 2.499 | 2.481 | 3.3284 |
| 300 | 2.499 | 2.45 | 3.7204 |
| 400 | 2.499 | 2.42 | 4.1128 |