JAJU528B August 2022 – January 2023 OPA388-Q1
Figure 3-30 HV Negative Error 100 V at No
Resistance
Figure 3-31 HV Negative Error 100 V at 100-kΩ
Resistance| HV BATTERY VOLTAGE (SUPPLIED AND MEASURED) |
MEASURED REFERENCE VOLTAGE | PEAK ISO_POS VOLTAGE | PEAK ISO_NEG VOLTAGE |
|---|---|---|---|
| 100 | 2.499 | 2.118 | 2.5438 |
| 200 | 2.499 | 1.696 | 2.5437 |
| 300 | 2.499 | 1.274 | 2.5438 |
| 400 | 2.499 | 0.852 | 2.5438 |
| HV BATTERY VOLTAGE (SUPPLIED AND MEASURED) |
MEASURED REFERENCE VOLTAGE | PEAK ISO_POS VOLTAGE | PEAK ISO_NEG VOLTAGE |
|---|---|---|---|
| 100 | 2.499 | 2.147 | 2.5736 |
| 200 | 2.499 | 1.755 | 2.6028 |
| 300 | 2.499 | 1.367 | 2.6327 |
| 400 | 2.499 | 0.971 | 2.6663 |