SPRADG6 April   2024 F28M36H33B2 , SM320LF2407A-EP , TMS320C28341 , TMS320C28343 , TMS320F2800132 , TMS320F2800133 , TMS320F2800135 , TMS320F2800137 , TMS320F2800152-Q1 , TMS320F2800153-Q1 , TMS320F2800154-Q1 , TMS320F2800155-Q1 , TMS320F2800156-Q1 , TMS320F2800157 , TMS320F2800157-Q1 , TMS320F280021 , TMS320F280021-Q1 , TMS320F280023 , TMS320F280023-Q1 , TMS320F280023C , TMS320F280025 , TMS320F280025-Q1 , TMS320F280025C , TMS320F280025C-Q1 , TMS320F280033 , TMS320F280034 , TMS320F280034-Q1 , TMS320F280036-Q1 , TMS320F280036C-Q1 , TMS320F280037 , TMS320F280037-Q1 , TMS320F280037C , TMS320F280037C-Q1 , TMS320F280038-Q1 , TMS320F280038C-Q1 , TMS320F280039 , TMS320F280039-Q1 , TMS320F280039C , TMS320F280039C-Q1 , TMS320F280040-Q1 , TMS320F280040C-Q1 , TMS320F280041 , TMS320F280041-Q1 , TMS320F280041C , TMS320F280041C-Q1 , TMS320F280045 , TMS320F280048-Q1 , TMS320F280048C-Q1 , TMS320F280049 , TMS320F280049-Q1 , TMS320F280049C , TMS320F280049C-Q1 , TMS320F28035-EP , TMS320F28050 , TMS320F28051 , TMS320F28052 , TMS320F28052-Q1 , TMS320F28052M-Q1 , TMS320F28054 , TMS320F28054-Q1 , TMS320F28062F-Q1 , TMS320F28064 , TMS320F28066-Q1 , TMS320F28068M , TMS320F28069F-Q1 , TMS320F28075 , TMS320F28075-Q1 , TMS320F28076 , TMS320F2810 , TMS320F2811 , TMS320F28333 , TMS320F28374D , TMS320F28374S , TMS320F28375D , TMS320F28375S , TMS320F28375S-Q1 , TMS320F28376D , TMS320F28376S , TMS320F28377D , TMS320F28377D-EP , TMS320F28377D-Q1 , TMS320F28377S , TMS320F28377S-Q1 , TMS320F28378D , TMS320F28378S , TMS320F28379D , TMS320F28379D-Q1 , TMS320F28379S , TMS320F28384D , TMS320F28384D-Q1 , TMS320F28384S , TMS320F28384S-Q1 , TMS320F28386D , TMS320F28386D-Q1 , TMS320F28386S , TMS320F28386S-Q1 , TMS320F28388D , TMS320F28388S , TMS320F28P550SJ , TMS320F28P559SJ-Q1 , TMS320F28P650DK , TMS320F28P659DK-Q1

 

  1.   1
  2.   Abstract
  3.   Trademarks
  4. 1C2000 Power Supply and Monitoring Solution
  5. 2Power Supply Solution for Safety Applications
    1. 2.1 ASIL-D Requirements
      1. 2.1.1 PMIC Solution
    2. 2.2 ASIL-B: Requirements
      1. 2.2.1 PMIC Solution
      2. 2.2.2 Discrete Solution
  6. 3Power Supply Solution for Non-Safety Applications
  7. 4Summary
  8. 5References

Power Supply Solution for Safety Applications

The ISO 26262 standard was originally published in 2011 to help address the functional safety of electrical and electronic systems. This standard uses a risk classification scheme called Automotive Safety Integrity Levels (ASILs) that express the capability of a safety-related function. The four ASILs identified by the standard are ASIL A, ASIL B, ASIL C and ASIL D, with ASIL A dictating the lowest capability and ASIL D being the most stringent.