DLPU048E August 2016 – July 2024
This command is used to configure ADC selections for the TIA1 Stage Monitor and low-side current sense gain in the TPS99000-Q1.
Write Parameters
| BYTE | BITS | DESCRIPTION |
|---|---|---|
| 1 | 7:4 | Reserved |
| 3:2 | Low-side current sense gain Gain for ADC0 input. 0x0: 24x 0x1: 12x 0x2: 9x 0x3: 24x | |
| 1:0 | TIA1 Stage Monitor Select Voltage monitor point within TIA1. Input to ADC30. 0x0: Stage A (Input offset output, Trim input) 0x1: Stage B (Trim output, Dark offset input) 0x2: Stage C (Gain #2 output, Gain #3 input) 0x3: Stage D (Gain #3 output, TIA output) |