The internal registers can be
programmed by following these steps:
- Drive the SEN pin low.
- Set the R/W bit to 0 (bit A15 of the 16-bit address) and bits
A[14:12] in the address field to 0.
- Initiate a serial interface cycle by specifying the address of
the register (A[11:0]) whose content is to be written.
- Write the 8-bit data that to be latched on the SCLK rising
edges.
Figure 7-35 shows the relevant timing requirements for the register write operation.