SBOA626 December 2025 OPA187 , OPA192 , OPA202 , OPA320
Up to this point, the document has considered the open-loop output impedance (ZO) to be a purely resistive value. Meaning, the value of ZO used in previous analysis was flat across frequency and did not contain any imaginary numbers. This section covers complex output impedance. In this instance, the term complex is used to describe an impedance that contains imaginary numbers from reactive impedance components. The magnitude of complex impedance is not flat across frequency. Furthermore, up to this point, the document uses the op amp open-loop output impedance as part of the stability analysis. Some op amp datasheets specify open-loop output impedance and others specify closed-loop output impedance. Depending on the specific stability problem, sometimes the closed-loop impedance can better facilitate analysis, and in other cases the open-loop impedance is better. This section shows how to mathematically convert open-loop output impedance to closed-loop and shows how to analyze stability using closed-loop output impedance. To clarify the difference between open-loop and closed-loop output impedance, this document designates ZO for open-loop output impedance and ZOUT for closed-loop.