SBOA626 December   2025 OPA187 , OPA192 , OPA202 , OPA320

 

  1.   1
  2.   Abstract
  3.   Trademarks
  4. 1Introduction
    1. 1.1 Simple Analogy Explaining Instability
    2. 1.2 Circuits With Possible Stability Issues
    3. 1.3 Simple Stability Correction Based on Datasheet Plots
    4. 1.4 Introducing Lab Tools and Measurements
  5. 2Stability Theory for Operational Amplifiers
    1. 2.1 Poles and Zeros
    2. 2.2 Operational Amplifier Model Requirements for Stability Verification
    3. 2.3 Stability Definitions Based on Control Loop Model
    4. 2.4 Graphing Loop-Gain Based on AOL and 1/β
    5. 2.5 Rate of Closure Stability Test
    6. 2.6 Indirect (Non-Invasive) Stability Tests
  6. 3Simulating Open-Loop Stability Tests
    1. 3.1 Breaking the Loop the Wrong Way
    2. 3.2 Breaking the Loop With LC Test Circuit
    3. 3.3 Differential Loop Break Test
  7. 4Stability Correction for Capacitive Load
    1. 4.1 Isolation Resistor (RISO) Method
    2. 4.2 Dual Feedback Method
      1. 4.2.1 RISO-Dual-Feedback With RL
      2. 4.2.2 Dual Feedback With RFX Method
    3. 4.3 Snubber Circuit for Compensating Power Amplifiers and Reference Drive
    4. 4.4 Noise Gain for Stability Compensation
    5. 4.5 Feedback Capacitor (CF) Compensation for Capacitive Load
  8. 5Stability Corrections for Capacitance on the Inverting Node
    1. 5.1 Input Capacitance Instability Due to Zero in 1/β
    2. 5.2 Feedback Capacitor Solves Stability Issue for Capacitance on the Inverting Node
    3. 5.3 Minimum, Balanced, and Maximum Feedback Capacitance
    4. 5.4 Transimpedance Case
  9. 6Complex Open-Loop and Closed-Loop Output Impedance
    1. 6.1 Converting Open-Loop Output Impedance to Closed-Loop Output Impedance
    2. 6.2 Open-Loop and Closed-Loop Model Test
    3. 6.3 Instability Due to Resonance From Complex Output Impedance
    4. 6.4 Impact of Internal Op Amp Topology on Output Impedance Versus Frequency
    5. 6.5 Other Factors Effecting Output Impedance
  10. 7AOL Impact on Stability
    1. 7.1 AOL Secondary Poles and Zeros
    2. 7.2 Modeling the AOL Secondary Poles and Zeros and Input Capacitance
    3. 7.3 Decompensated Op Amps and Stability
    4. 7.4 The Impact of Closed-Loop Gain on Stability
  11. 8Common Problems in Stability Analysis
  12. 9References

Converting Open-Loop Output Impedance to Closed-Loop Output Impedance

Equation 87 shows how to translate open-loop output impedance (ZO) to closed-loop output impedance (ZOUT). Notice that ZO is divided by 1+β × AOL(f) which is generally a very large value at low frequency. Thus, at low frequency ZOUT is very small. As frequency increases AOL(f) decreases by 20dB/dec, so the closed-loop output impedance increases by 20dB/dec. Meaning, when ZO is resistive (flat versus frequency), ZOUT looks inductive (increasing by 20dB/dec over frequency). This principle can be shown mathematically by substituting AOL(f) using a single pole AOL model (see Equation 87 and Equation 88). Using algebra to simplify Equation 88 yields Equation 89. Inspecting Equation 89 shows that ZOUT has a zero at the dominant pole frequency of AOL, and the pole at the bandwidth limit of the amplifier. Between the low frequency dominant pole and the high frequency bandwidth limit the ZOUT looks inductive. Also, since equation translating open-loop to closed-loop output impedance includes β, the closed-loop output impedance is gain dependent. Figure 6-2 shows the open-loop output impedance for OPA320 and Figure 6-3 shows the closed-loop impedance for several different gains.

Equation 87. Z O U T f = Z O 1 + β × A O L f
Equation 88. Z O U T f = Z O 1 + β × A O L _ D C 1 + s / ω D O M
Equation 89. Z O U T f = K × s ω D O M + 1 s A O L _ D C × β + 1 × ω D O M + 1 = K × s ω D O M + 1 s ω P + 1
OPA187 OPA202 OPA320 OPA192 Op Amp Behavioral Model With Single
          Dominant Pole
          (OPA320) Figure 6-1 Op Amp Behavioral Model With Single Dominant Pole (OPA320)
OPA187 OPA202 OPA320 OPA192 Open-Loop Output Impedance
            ZO for
          OPA320 Figure 6-2 Open-Loop Output Impedance ZO for OPA320
OPA187 OPA202 OPA320 OPA192 Closed-Loop Output Impedance
            ZOUT for
          OPA320 Figure 6-3 Closed-Loop Output Impedance ZOUT for OPA320