SBOSAI8A March 2025 – July 2025 INA630
PRODUCTION DATA
Instrumentation amplifiers can set the gain by a single resistor, whereas in the INA630, the gain and thus the gain accuracy is determined by the relative match of the external feedback resistor network R1 and R2.
An advantage of this configuration becomes evident for temperature drifts. In traditional instrumentation amplifiers, the external resistor must match the internal monolithic resistors. Discrete resistors are available with a ratio temperature coefficient of < 10ppm/°C to achieve excellent gain drift performance.