SBOSAK8
March 2025
INA950-SEP
PRODUCTION DATA
1
1
Features
2
Applications
3
Description
4
Pin Configuration and Functions
5
Specifications
5.1
Absolute Maximum Ratings
5.2
ESD Ratings
5.3
Recommended Operating Conditions
5.4
Thermal Information
5.5
Electrical Characteristics
5.6
Typical Characteristics
6
Detailed Description
6.1
Overview
6.2
Functional Block Diagram
6.3
Feature Description
6.3.1
Amplifier Input Common-Mode Range
6.3.2
Input-Signal Bandwidth
6.3.3
Low Input Bias Current
6.3.4
Low VSENSE Operation
6.3.5
Wide Fixed-Gain Output
6.4
Device Functional Modes
6.4.1
Unidirectional Operation
6.4.2
High Signal Throughput
7
Application and Implementation
7.1
Application Information
7.1.1
RSENSE and Device Gain Selection
7.1.2
Input Filtering
7.2
Typical Application
7.2.1
Design Requirements
7.2.2
Detailed Design Procedure
7.2.2.1
Overload Recovery With Negative VSENSE
7.2.3
Application Curve
7.3
Power Supply Recommendations
7.4
Layout
7.4.1
Layout Guidelines
7.4.2
Layout Examples
8
Device and Documentation Support
8.1
Documentation Support
8.1.1
Related Documentation
8.2
Receiving Notification of Documentation Updates
8.3
Support Resources
8.4
Trademarks
8.5
Electrostatic Discharge Caution
8.6
Glossary
9
Revision History
10
Mechanical, Packaging, and Orderable Information
10.1
Mechanical Data
5.3
Recommended Operating Conditions
over operating free-air temperature range (unless otherwise noted)
MIN
NOM
MAX
UNIT
V
CM
Common-mode input range
(1)
V
S
48
80
V
V
S
Operating supply range
2.7
5.5
V
T
A
Ambient temperature
–55
125
°C
(1)
Common-mode voltage can go below V
S
under certain conditions. See
Minimum Common-Mode Voltage vs Supply
or additional information on operating range.