SDAA502 August   2026 TMCS2100-Q1

 

  1.   1
  2.   Abstract
  3.   Trademarks
  4. 1Introduction
  5. 2Error Measurement
    1. 2.1 Overview
      1. 2.1.1 Measurement Accuracy
        1. 2.1.1.1 Offset Cancellation
        2. 2.1.1.2 Signal Magnitude
    2. 2.2 Balanced Three-Phase Calibration
      1. 2.2.1 Equipment Requirements
      2. 2.2.2 Test Configuration
      3. 2.2.3 Calibration Procedure
    3. 2.3 Crosstalk Matrix Calibration
      1. 2.3.1 Theoretical Foundation
        1. 2.3.1.1 Crosstalk Model
        2. 2.3.1.2 Matrix Population by Single-Phase Excitation
        3. 2.3.1.3 Combined-Field Amplitude Under Balanced Operation
      2. 2.3.2 Equipment Requirements
      3. 2.3.3 Calibration Procedure
      4. 2.3.4 Worked Example
      5. 2.3.5 Runtime Crosstalk Cancellation
        1. 2.3.5.1 Implementation
    4. 2.4 Paired-Phase Injection Calibration
      1. 2.4.1 Theoretical Foundation
      2. 2.4.2 Equipment Requirements
      3. 2.4.3 Calibration Procedure
    5. 2.5 Method Comparison
  6. 3Sensitivity Adjustment Procedure
    1. 3.1 Formula
    2. 3.2 Calculation Example
    3. 3.3 Frequency Compensation Values Adjustment
      1. 3.3.1 Step 1: Convert Frequency Compensation Codes to Error Percentages
      2. 3.3.2 Step 2: Compute New Frequency Compensation Codes
      3. 3.3.3 Calculation Example (Continued for Frequency Compensation)
    4. 3.4 GUI Calculator
  7. 4Troubleshooting
  8. 5Summary
  9. 6References

Equipment Requirements

Note: If the inverter drive hardware is available and controllable at EOL, the inverter can serve as the three-phase current source, eliminating the need for external excitation equipment.
Item Requirement
Three-phase current sourceBalanced sinusoidal output when connected to appropriate load
Balanced loadThree-phase resistive or RL load matched to source power inputs; alternatively synchronized electronic loads
Reference current sensorsOne per phase; accuracy ≤ 0.1 %
TMCS2100-Q1 programming interfaceI2C access to all TMCS2100-Q1 devices