SDAA502 August   2026 TMCS2100-Q1

 

  1.   1
  2.   Abstract
  3.   Trademarks
  4. 1Introduction
  5. 2Error Measurement
    1. 2.1 Overview
      1. 2.1.1 Measurement Accuracy
        1. 2.1.1.1 Offset Cancellation
        2. 2.1.1.2 Signal Magnitude
    2. 2.2 Balanced Three-Phase Calibration
      1. 2.2.1 Equipment Requirements
      2. 2.2.2 Test Configuration
      3. 2.2.3 Calibration Procedure
    3. 2.3 Crosstalk Matrix Calibration
      1. 2.3.1 Theoretical Foundation
        1. 2.3.1.1 Crosstalk Model
        2. 2.3.1.2 Matrix Population by Single-Phase Excitation
        3. 2.3.1.3 Combined-Field Amplitude Under Balanced Operation
      2. 2.3.2 Equipment Requirements
      3. 2.3.3 Calibration Procedure
      4. 2.3.4 Worked Example
      5. 2.3.5 Runtime Crosstalk Cancellation
        1. 2.3.5.1 Implementation
    4. 2.4 Paired-Phase Injection Calibration
      1. 2.4.1 Theoretical Foundation
      2. 2.4.2 Equipment Requirements
      3. 2.4.3 Calibration Procedure
    5. 2.5 Method Comparison
  6. 3Sensitivity Adjustment Procedure
    1. 3.1 Formula
    2. 3.2 Calculation Example
    3. 3.3 Frequency Compensation Values Adjustment
      1. 3.3.1 Step 1: Convert Frequency Compensation Codes to Error Percentages
      2. 3.3.2 Step 2: Compute New Frequency Compensation Codes
      3. 3.3.3 Calculation Example (Continued for Frequency Compensation)
    4. 3.4 GUI Calculator
  7. 4Troubleshooting
  8. 5Summary
  9. 6References

Abstract

The TMCS2100-Q1 is an ambient magnetic field sensor that measures the combined magnetic field from currents in three-phase systems. Devices are pre-programmed by the user with values tuned to a specific bus bar geometry during characterization. Manufacturing tolerances in the final assembly can shift the sensor position relative to the bus bars, introducing amplitude errors in the sensor output that can be addressed on the manufacturing line. This application note describes end-of-line (EOL) calibration procedures for measuring the per-unit error in a manufacturing flow, as well as how to correct these per-unit errors by adjusting the Gain 2 and frequency compensation register values.