SFFSAY3 January   2026 F29H850DM , F29H850DU , F29H850TU , F29H859TU-Q1 , F29P329SM-Q1 , F29P589DM-Q1 , F29P589DU-Q1 , TMCS1123 , TMCS1123-Q1 , TPS650362-Q1 , TPS650364-Q1 , TPS650365-Q1 , TPS650366-Q1

 

  1.   1
  2.   Abstract
  3.   Trademarks
  4. 1Introduction
    1. 1.1 Background
    2. 1.2 HW/SW FuSa Analysis Process
      1. 1.2.1 Item Definition
      2. 1.2.2 Functional Safety Goal
      3. 1.2.3 Functional Safety Concept
      4. 1.2.4 Technical Safety Concept
      5. 1.2.5 HW/SW Safety Requirement
      6. 1.2.6 Dependent‑failure Analysis
    3. 1.3 TI Collaterals
      1. 1.3.1 TI Components Category
      2. 1.3.2 FuSa Collaterals for Safety MCU
  5. 2FuSa Concepts of OBC System
    1. 2.1 Item Definition
      1. 2.1.1 Item Functions
      2. 2.1.2 System Boundaries
      3. 2.1.3 External Interfaces
      4. 2.1.4 Operation Modes
    2. 2.2 Functional Safety Goal
    3. 2.3 Functional Safety Concept
    4. 2.4 Technical Safety Concept
    5. 2.5 HW/SW Safety Requirement
    6. 2.6 Dependent‑Failure Analysis
  6. 3FuSa Components of OBC System
    1. 3.1 Components Overview
    2. 3.2 Microcontroller
      1. 3.2.1 CPU
      2. 3.2.2 ADC Sample
      3. 3.2.3 PWM Generation
      4. 3.2.4 CMPSS
      5. 3.2.5 Data Transmission
      6. 3.2.6 Fault Signal Monitor and Safe State Control
    3. 3.3 Power Management IC
      1. 3.3.1 MCU Monitor
      2. 3.3.2 Shutdown Sequence
      3. 3.3.3 Power Supply
    4. 3.4 System Basis Chips
      1. 3.4.1 CAN Communication
      2. 3.4.2 Supply Voltage Rail Monitoring
      3. 3.4.3 SPI/Processor Communication
      4. 3.4.4 Device Internal EEPROM
    5. 3.5 Power Supply and Supervisor
    6. 3.6 Gate Driver
    7. 3.7 Voltage Sensor
    8. 3.8 Current Sensor
    9. 3.9 Temperature Sensor
  7. 4Summary
  8. 5References

Current Sensor

In a typical OBC application, current sensors are required for close-loop control and overcurrent or short-circuit protection. Hall-effect based components are one option, which can be used for both AC and DC current measurements. Hall-effect based features low-ohmic lead frame path reducing power dissipation, and does not require any external passive components, isolated supplies, or control signals on the HV side.

TMCS1133-Q1 is a galvanically isolated hall-effect current sensor providing high levels of reliable reinforced isolation working voltage, ambient field rejection and high current carrying capability. Industry leading accuracy was achieved with a factory-trimmed sensitivity error 0.4% at 25°C and sensitivity error 0.5% over the full operating temperature. The function block diagram is shown in Figure 3-5.

 Function Block Diagram of
                    TMCS1133-Q1 Figure 3-5 Function Block Diagram of TMCS1133-Q1

TMCS1133-Q1 offers a fast digital overcurrent detection response. This can be used to trigger a warning or initiate a system shutdown to prevent damage from excessive current flow caused by short circuits or other unintended system conditions. The OC threshold can be configured on both bidirectional and unidirectional devices to assert based on a signal from half to over twice the full-scale analog measurement range.

The benefits of using OC output instead of VOUT to detect overcurrent events are higher dynamic range with higher sensitivity and lower overall signal noise from lower analog signal bandwidth. However, VOUT pin can also be used as a redundant OC protection feature by using CMPSS module of MCU. For VOUT pin OC protection, lower OC threshold can be set to cover the event with a smaller current but a longer duration. It can also cover the OC events when the SPF occurs in the OC pin path.

Built-in self-diagnostic features are incorporated in the TMCS1133-Q1 to warn when operating conditions invalidate current sensor measurements. Two critical conditions being monitored are sensor temperature and sensitivity.

  • High input currents, coupled with elevated ambient temperatures and printed circuit board thermal design can cause the TMCS1133-Q1 to overheat and be permanently damaged by exceeding maximum allowed junction temperatures. A thermal alert occurs when the internal temperature approaches the maximum allowed junction temperature.
  • Sensor sensitivity and offset are constantly monitored inside TMCS1133-Q1. A sensor alert occurs in the unlikely event hall sensor sensitivity or offset is out of range compared with factory set limits.

The active-low ALERT output signal can be used to decipher which of four diagnostic states the TMCS1133-Q1 resides. The duty cycle of the 8kHz PWM output signal indicates which, neither, or both thermal and sensor operating condition warnings exist.

Shunt-resistor based designs are the alternative in current sensing. The AMC0302D-Q1 is a precision, isolated amplifier with an output separated from the input circuitry by an isolation barrier that is highly resistant to magnetic interference. The input of the AMC0302D-Q1 is optimized for direct connection to a low-impedance shunt resistor or other low-impedance voltage source with low signal levels. The excellent DC accuracy and low temperature drift supports accurate current control in OBC application. Figure 3-6 shows the block diagram.

 Block Diagram of
                    AMC0302D-Q1 Figure 3-6 Block Diagram of AMC0302D-Q1

The integrated missing-shunt and missing high-side supply detection features simplify system-level design and diagnostics. Figure 3-7 shows the fail-safe mode, in which the AMC0302D-Q1 outputs a negative differential output voltage that does not occur under normal operating conditions.

 Output Behavior of the
                    AMC0302D-Q1 Figure 3-7 Output Behavior of the AMC0302D-Q1

Use the maximum fail-safe voltage as a reference value for fail-safe detection on system level. The fail-safe output is active in two cases:

  • When the high-side supply is missing or below the VDD1 UVLO threshold.
  • When the common-mode input voltage, that is VCM = (VINP + VINN) / 2, exceeds the common-mode overvoltage detection level.

If the current sensing circuit is only used for overcurrent protection and not for current control, an isolated comparator is a very suitable solution. Generally, it can be regarded as the second chain of redundant sensing for FuSa. The AMC23C12-Q1 is an isolated window comparator with a short response time. The comparison window is centered around 0V, meaning that the comparator trips if the absolute value of the input voltage exceeds the trip threshold value. The block diagram is shown in Figure 3-8.

 Block Diagram of the
                    AMC23C12-Q1 Figure 3-8 Block Diagram of the AMC23C12-Q1